CBS 2019
CBSMD教育中心
English

药物涂层球囊

科研文章

荐读文献

A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease Prospective, large-scale multicenter trial for the use of drug-coated balloons in coronary lesions: The DCB-only All-Comers Registry Percutaneous coronary intervention with drug-coated balloon-only strategy in stable coronary artery disease and in acute coronary syndromes: An all-comers registry study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review

Original Research2019 Jan 16. [Epub ahead of print]

JOURNAL:Cardiovasc Interv Ther. Article Link

Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease

Funatsu A, Kobayashi T, Mizobuchi M et al. Keywords: Coronary dissection; Paclitaxel-coated balloon; Small vessel coronary artery disease

ABSTRACT


The mechanism of how angiographic results following paclitaxel-coated balloon (PCB) treatment for small vessel disease affect patient outcome remains unknown. In the present study, we aimed to investigate the correlation between coronary dissection immediately after PCB angioplasty and midterm outcome. From March 2014 to March 2017, 171 consecutive patients with 228 native coronary artery lesions who received PCB angioplasty at a single center were enrolled retrospectively. Lesions with a reference vessel diameter > 2.8 mm were excluded. There were dissections in 80% of the lesions immediately following PCB angioplasty. Of these, 38% were type A, 29% were type B, and 13% were type C or more severe dissection. No patient required revascularization during hospitalization. We were able to follow 159 patients (212 lesions) clinically for > 6 months, from among whom target lesion revascularization (TLR) was performed in 7% of the patients. Follow-up angiography was performed on 143 lesions (67%), and complete healing of all dissections was noted. The rates of restenosis and late lumen enlargement were 12% and 56%, respectively. Multivariate analysis identified that a bending lesion was an independent predictor of TLR, and type C-E dissection and imaging device use were independent predictors of restenosis. Conversely, lesions with type B dissection had a larger net gain than lesions with type A or no dissection. Leaving the dissection uncovered after PCB angioplasty seems to be safe, resulting in a low acute event rate. The type B dissection after PCB angioplasty was the most therapeutic dissection.