CBS 2019
CBSMD教育中心
English

光学相关断层扫描

科研文章

荐读文献

Impact of an optical coherence tomography guided approach in acute coronary syndromes: A propensity matched analysis from the international FORMIDABLE-CARDIOGROUP IV and USZ registry Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromiummetallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study Nonculprit Lesion Plaque Morphology in Patients With ST-Segment–Elevation Myocardial Infarction: Results From the COMPLETE Trial Optical Coherence Tomography Substudys Coronary Atherosclerosis T1-Weighed Characterization With Integrated Anatomical Reference: Comparison With High-Risk Plaque Features Detected by Invasive Coronary Imaging Optical coherence tomography predictors of target vessel myocardial infarction after provisional stenting in patients with coronary bifurcation disease Histopathological validation of optical coherence tomography findings of the coronary arteries The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion After Provisional Stenting of Coronary Bifurcation Lesions

Original Research2014 Dec;10(8):916-23.

JOURNAL:EuroIntervention. Article Link

Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study

Chieffo A, Buchanan GL, Colombo A et al. Keywords: DES; ACS; OCT

ABSTRACT


AIMSTo our knowledge, no randomised study has compared rates of uncovered stent struts in everolimus (EES) vs. new-generation zotarolimus-eluting (ZES-R) stents in acute coronary syndrome (ACS). The aim of our study was to evaluate the completeness of neointimal coverage with optical coherence tomography (OCT) in ACS patients treated with drug-eluting stents (DES) comparing EES versus new-generation ZES-R.


METHODS AND RESULTS - All eligible ACS patients admitted to four Italian centres with a clinical indication for culprit lesion intervention were randomised 1:1 to EES or ZES-R. The primary study endpoint was the percentage of uncovered stent struts evaluated by optical coherence tomography (OCT) at six months. Secondary endpoints were the percentage of malapposed stent struts, percent neointimal hyperplasia cross-sectional area (CSA) and major adverse cardiac events (MACE) at six months. A total of 60 patients were randomised to EES (n=29) or ZES-R (n=31). No differences were observed in baseline characteristics between the two groups. Overall, 31.7% presented with STEMI, of which 68.4% were anterior. The other patients comprised 41.7% NSTEMI and 26.7% troponin-negative ACS. A mean of 1.3±0.6 lesions were treated per patient, with a mean of 1.3±0.5 stents per lesion. At 30 days there was one sudden death. Six-month OCT analysis was performed in 25 lesions in the EES group and in 24 lesions in the ZES-R group. There was no difference in the primary endpoint of uncovered stent struts between groups (EES 6.42% [3.27, 9.57] vs. ZES-R 7.07% [3.22, 10.92]; p=0.80). Furthermore, there were no differences between groups in the percentage of malapposed stent struts, either with (EES 1.19% [0.34, 2.04] vs. ZES-R 0.85% [0.40, 1.30]; p=0.49) or without coverage (EES 1.06% [0.12, 2.01] vs. ZES-R 0.24% [0.05, 0.44]; p=0.09). Percent neointima CSA was similar in both groups (EES 37.0% [18.6, 55.3] vs. ZES-R 26.6% [18.4, 34.8]; p=0.31). At six-month clinical follow-up, no additional patients died or suffered MI. There were four MACE in the EES group and one in the ZES-R group.

CONCLUSIONS - In our study, in patients presenting with ACS, both EES and ZES-R had low percentages of malapposed and uncovered stent struts at six-month OCT analysis.

TRIAL REGISTRATION - ClinicalTrials.gov NCT01239654.