Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Optical Coherence Tomography-Guided Percutaneous Coronary Intervention in ST-Segment-Elevation Myocardial Infarction: A Prospective Propensity-Matched Cohort of the Thrombectomy Versus Percutaneous Coronary Intervention Alone Trial Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation Spontaneous Coronary Artery Dissection: Pathophysiological Insights From Optical Coherence Tomography Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium) Angiography Alone Versus Angiography Plus Optical Coherence Tomography to Guide Percutaneous Coronary Intervention: Outcomes From the Pan-London PCI Cohort Comparison of Coronary Intimal Plaques by Optical Coherence Tomography in Arteries With Versus Without Internal Running Vasa Vasorum Joint consensus on the use of OCT in coronary bifurcation lesions by the European and Japanese bifurcation clubs Coronary Artery Intraplaque Microvessels by Optical Coherence Tomography Correlate With Vulnerable Plaque and Predict Clinical Outcomes in Patients With Ischemic Angina Changes in Coronary Plaque Composition in Patients With Acute Myocardial Infarction Treated With High-Intensity Statin Therapy (IBIS-4): A Serial Optical Coherence Tomography Study

Original Research2019 Mar 27. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients

Matsuhiro Y, Matsunaga-Lee Y, Nakamura D et al. Keywords: chronic renal disease; coronary artery disease; OCT; stents

ABSTRACT


AIM - Clinical outcomes after percutaneous coronary intervention (PCI) in hemodialysis (HD) patients are significantly worse than those in non-HD patients. Optical coherence tomography (OCT) is a high resolution imaging modality and provides a detailed assessment of post-interventional abnormal findings that influence worse clinical outcomes. However, little is known about the abnormal post-stent OCT findings in HD patients. Therefore, in this study, we compared the abnormal post-stent OCT findings between HD and non-HD patients.


METHODS - One hundred thirty-nine consecutive OCT guided PCI (21 lesions in HD patients and 118 lesions in non-HD patients) were enrolled. We compared the post-stent OCT findings, including the edge dissections, under expansion index (minimum stent area/mean reference area), and stent eccentricity index (minimum stent diameter/maximum stent diameter) between HD and non-HD patients. We also compared the device-oriented clinical events (DoCEs) at 8 months of follow up.


RESULTS - There was a significantly higher prevalence of distal edge dissections (16.7% vs. 2.8%, P = 0.011) in HD patients. HD patients had a significantly lower under expansion index (0.76 ± 0.21 vs. 0.85 ± 0.14, P = 0.029) and stent eccentricity index (0.82 ± 0.09 vs. 0.88 ± 0.18, P = 0.018). The cumulative rate of DoCEs was significantly higher in the HD patients (23.8% vs. 5.2%, P = 0.013).


CONCLUSIONS - A higher prevalence of distal edge dissections, under expansion and stent eccentricity were detected by the detailed OCT findings in HD patients.

 

© 2019 Wiley Periodicals, Inc.