Utilization and Outcomes of Measuring Fractional Flow Reserve in Patients With Stable Ischemic Heart Disease Physiological Stratification of Patients With Angina Due to Coronary Microvascular Dysfunction Coronary Physiology in the Cardiac Catheterization Laboratory Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Diagnostic accuracy of intracoronary optical coherence tomography-derived fractional flow reserve for assessment of coronary stenosis severity Comparison of Coronary Computed Tomography Angiography, Fractional Flow Reserve, and Perfusion Imaging for Ischemia Diagnosis Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps) Fractional flow reserve in clinical practice: from wire-based invasive measurement to image-based computation Coronary Flow Reserve in the Instantaneous Wave-Free Ratio/Fractional Flow Reserve Era: Too Valuable to Be Neglected

Clinical TrialAugust 2017, Volume 10, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation

Piroth Z, Toth GG, De Bruyne B et al. Keywords: acute coronary syndromedrug-eluting stenthospitalizationmyocardial infarctionpercutaneous coronary intervention

ABSTRACT


Background The predictive value of fractional flow reserve (FFR) measured immediately after percutaneous coronary intervention (PCI) with drug-eluting stent placement has not been prospectively investigated. We investigated the potential of post-PCI FFR measurements to predict clinical outcome in patients from FAME 1 and 2 trials (Fractional Flow Reserve or Angiography for Multivessel Evaluation).


Methods and Results All patients of FAME 1 and FAME 2 who had post-PCI FFR measurement were included. The primary outcome was vessel-oriented composite end point at 2 years, defined as vessel-related cardiovascular death, vessel-related spontaneous myocardial infarction, and ischemia-driven target vessel revascularization. Eight hundred thirty-eight vessels in 639 patients were analyzed. Baseline FFR values did not differ between vessels with versus without vessel-oriented composite end point (0.66±0.11 versus 0.63±0.14, respectively; P=0.207). Post-PCI FFR was significantly lower in vessels with vessel-oriented composite end point (0.88±0.06 versus 0.90±0.06, respectively; P=0.019). Comparing the 2-year outcome of lower and upper tertiles of post-PCI FFR significant difference was found favoring upper tertile in terms of overall vessel-oriented composite end point (9.2% versus 3.8%, respectively; hazard ratio, 1.46; 95% confidence interval, 1.02–2.08; P=0.037) and target vessel revascularization (7.0% versus 2.4%, respectively; hazard ratio, 1.59; 95% confidence interval, 1.03–2.46; P=0.037). When adjusted to sex, hypertension, diabetes mellitus, target vessel, serial stenosis, and baseline percentage diameter stenosis, a strong trend was preserved in terms of target vessel revascularization (harzard ratio, 1.55; 95% confidence interval, 0.97–2.46; P=0.066), favoring the upper tertile. Post-PCI FFR of 0.92 was found to have the highest diagnostic accuracy; however, the positive likelihood ratio remained low (<1.4).

Conclusions A higher post-PCI FFR value is associated with a better vessel-related outcome. However, its predictive value is too low to advocate its use as a surrogate clinical end point.