CBS 2019
CBSMD教育中心
English

经导管主动脉瓣置换

科研文章

荐读文献

Balloon Aortic Valvuloplasty as a Bridge to Aortic Valve Replacement: A Contemporary Nationwide Perspective Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Implantation 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Comparison of Early Surgical or Transcatheter Aortic Valve Replacement Versus Conservative Management in Low-Flow, Low-Gradient Aortic Stenosis Using Inverse Probability of Treatment Weighting: Results From the TOPAS Prospective Observational Cohort Study 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Short Length of Stay After Elective Transfemoral Transcatheter Aortic Valve Replacement Is Not Associated With Increased Early or Late Readmission Risk

Review ArticleVolume 74, Issue 12, September 2019

JOURNAL:J Am Coll Cardiol. Article Link

Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

DKolte, GJ Vlahakes, IF Palacios et al. Keywords: death; low risk; surgical aortic valve replacement; transcatheter aortic valve implantation; transcatheter aortic valve replacement

ABSTRACT


BACKGROUND- Transcatheter aortic valve replacement (TAVR) has emerged as a safe and effective therapeutic option for patients with severe aortic stenosis (AS) who are at prohibitive, high, or intermediate risk for surgical aortic valve replacement (SAVR). However, in low-risk patients, SAVR remains the standard therapy in current clinical practice.

 

OBJECTIVES - This study sought to perform a meta-analysis of randomized controlled trials (RCTs) comparing TAVR versus SAVR in low-risk patients.

 

METHODS - Electronic databases were searched from inception to March 20, 2019. RCTs comparing TAVR versus SAVR in low-risk patients (Society of Thoracic Surgeons Predicted Risk of Mortality [STS-PROM] score <4%) were included. Primary outcome was all-cause death at 1 year. Random-effects models were used to calculate pooled risk ratio (RR) and corresponding 95% confidence interval (CI).

 

RESULTS- The meta-analysis included 4 RCTs that randomized 2,887 patients (1,497 to TAVR and 1,390 to SAVR). The mean age of patients was 75.4 years, and the mean STS-PROM score was 2.3%. Compared with SAVR, TAVR was associated with significantly lower risk of all-cause death (2.1% vs. 3.5%; RR: 0.61; 95% CI: 0.39 to 0.96; p = 0.03; I2 = 0%) and cardiovascular death (1.6% vs. 2.9%; RR: 0.55; 95% CI: 0.33 to 0.90; p = 0.02; I2 = 0%) at 1 year. Rates of new/worsening atrial fibrillation, life-threatening/disabling bleeding, and acute kidney injury stage 2/3 were lower, whereas those of permanent pacemaker implantation and moderate/severe paravalvular leak were higher after TAVR versus SAVR. There were no significant differences between TAVR versus SAVR for major vascular complications, endocarditis, aortic valve re-intervention, and New York Heart Association functional class II.

 

CONCLUSIONS- In this meta-analysis of RCTs comparing TAVR versus SAVR in low-risk patients, TAVR was associated with significantly lower risk of all-cause death and cardiovascular death at 1 year. These findings suggest that TAVR may be the preferred option over SAVR in low-risk patients with severe AS who are candidates for bioprosthetic AVR.