CBS 2019
CBSMD教育中心
中 文

Other Relevant Articles

Abstract

Recommended Article

Oxidative Stress and Cardiovascular Risk: Obesity, Diabetes, Smoking, and Pollution: Part 3 of a 3-Part Series ACC Clinical Bulletin Focuses on Cardiac Implications of Coronavirus (COVID-19) CSC Expert Consensus on Principles of Clinical Management of Patients with Severe Emergent Cardiovascular Diseases during the COVID-19 Epidemic COVID-19 and Thrombotic or Thromboembolic Disease: Implications for Prevention, Antithrombotic Therapy, and Follow-up Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease Hemodynamic Response to Nitroprusside in Patients With Low-Gradient Severe Aortic Stenosis and Preserved Ejection Fraction Inflammation: A New Target For CAD Treatment and Prevention Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation

Review ArticleVolume 69, Issue 25, June 2017, Pages 3055-3066

JOURNAL:J Am Coll Cardiol. Article Link

Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents

S Sorrentino , G Giustino, GD Dangas et al Keywords: bioresorbable vascular scaffold; everolimus-eluting

ABSTRACT


Background - Recent evidence suggests that bioresorbable vascular scaffolds (BVS) are associated with an excess of thrombotic complications compared with metallic everolimus-eluting stents (EES).


Objectives - This study sought to investigate the comparative effectiveness of the Food and Drug Administration-approved BVS versus metallic EES in patients undergoing percutaneous coronary intervention at longest available follow-up.


Methods - The authors searched MEDLINE, Scopus, and web sources for randomized trials comparing BVS and EES. The primary efficacy and safety endpoints were target lesion failure and definite or probable stent thrombosis, respectively.


Results - Seven trials were included: in sum, 5,583 patients were randomized to receive either the study BVS (n = 3,261) or the EES (n = 2,322). Median time of follow-up was 2 years (range 2 to 3 years). Compared with metallic EES, risk of target lesion failure (9.6% vs. 7.2%; absolute risk difference: +2.4%; risk ratio: 1.32; 95% confidence interval: 1.10 to 1.59; number needed to harm: 41; p = 0.003; I2 = 0%) and stent thrombosis (2.4% vs. 0.7%; absolute risk difference: +1.7%; risk ratio: 3.15; 95% confidence interval: 1.87 to 5.30; number needed to harm: 60; p < 0.0001; I2 = 0%) were both significantly higher with BVS. There were no significant differences in all-cause or cardiovascular mortality between groups. The increased risk for ST associated with BVS was concordant across the early (<30 days), late (30 days to 1 year), and very late (>1 year) periods (pinteraction = 0.49).


Conclusions - Compared with metallic EES, the BVS appears to be associated with both lower efficacy and higher thrombotic risk over time. (Bioresorbable vascular scaffold compare to everolimus stents in long term follow up; CRD42017059993).