CBS 2019
CBSMD教育中心
中 文

Drug Coated Balloon

Abstract

Recommended Article

Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review Changes in high-sensitivity troponin after drug-coated balloon angioplasty for drug-eluting stent restenosis Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort Drug-eluting balloons in coronary interventions: the quiet revolution? Outcomes with drug-coated balloons in small-vessel coronary artery disease Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Benefits with drug-coated balloon as compared to a conventional revascularization strategy for the treatment of coronary and non-coronary arterial disease: a comprehensive meta-analysis of 45 randomized trials Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease

Original Research2019 Jan 16. [Epub ahead of print]

JOURNAL:Cardiovasc Interv Ther. Article Link

Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease

Funatsu A, Kobayashi T, Mizobuchi M et al. Keywords: Coronary dissection; Paclitaxel-coated balloon; Small vessel coronary artery disease

ABSTRACT


The mechanism of how angiographic results following paclitaxel-coated balloon (PCB) treatment for small vessel disease affect patient outcome remains unknown. In the present study, we aimed to investigate the correlation between coronary dissection immediately after PCB angioplasty and midterm outcome. From March 2014 to March 2017, 171 consecutive patients with 228 native coronary artery lesions who received PCB angioplasty at a single center were enrolled retrospectively. Lesions with a reference vessel diameter > 2.8 mm were excluded. There were dissections in 80% of the lesions immediately following PCB angioplasty. Of these, 38% were type A, 29% were type B, and 13% were type C or more severe dissection. No patient required revascularization during hospitalization. We were able to follow 159 patients (212 lesions) clinically for > 6 months, from among whom target lesion revascularization (TLR) was performed in 7% of the patients. Follow-up angiography was performed on 143 lesions (67%), and complete healing of all dissections was noted. The rates of restenosis and late lumen enlargement were 12% and 56%, respectively. Multivariate analysis identified that a bending lesion was an independent predictor of TLR, and type C-E dissection and imaging device use were independent predictors of restenosis. Conversely, lesions with type B dissection had a larger net gain than lesions with type A or no dissection. Leaving the dissection uncovered after PCB angioplasty seems to be safe, resulting in a low acute event rate. The type B dissection after PCB angioplasty was the most therapeutic dissection.