Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Comparative efficacy of two paclitaxel-coated balloons with different excipient coatings in patients with coronary in-stent restenosis: A pooled analysis of the Intracoronary Stenting and Angiographic Results: Optimizing Treatment of Drug Eluting Stent In-Stent Restenosis 3 and 4 trials Outcomes after drug-coated balloon treatment for patients with calcified coronary lesions Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons Contemporary use of drug-coated balloons in coronary artery disease: Where are we now? The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis): Angiographic Results and 1-Year Clinical Outcomes Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Original Research2018 Mar;197:35-42.

JOURNAL:Am Heart J. Article Link

Comparison of drug-eluting stents and drug-coated balloon for the treatment of drug-eluting coronary stent restenosis: A randomized RESTORE trial

Wong YTA, Kang DY, Park DW et al. Keywords: drug-eluting coronary stent restenosis; drug-coated balloon

ABSTRACT


BACKGROUND - This study sought to evaluate the optimal treatment for in-stent restenosis (ISR) of drug-eluting stents (DESs).


METHODS - This is a prospective, multicenter, open-label, randomized study comparing the use of drug-eluting balloon (DEB) versus second-generation everolimus-eluting stent for the treatment of DES ISR. The primary end point was in-segment late loss at 9-month routine angiographic follow-up.

RESULTS - A total of 172 patients were enrolled, and 74 (43.0%) patients underwent the angiographic follow-up. The primary end point was not different between the 2 treatment groups (DEB group 0.15±0.49 mm vs DES group 0.19±0.41 mm, P=.54). The secondary end points of in-segment minimal luminal diameter (MLD) (1.80±0.69 mm vs 2.09±0.46 mm, P=.03), in-stent MLD (1.90±0.71 mm vs 2.29±0.48 mm, P=.005), in-segment percent diameter stenosis (34%±21% vs 26%±15%, P=.05), and in-stent percent diameter stenosis (33%±21% vs 21%±15%, P=.002) were more favorable in the DES group. The composite of death, myocardial infarction, or target lesion revascularization at 1 year was comparable between the 2 groups (DEB group 7.0% vs DES group 4.7%, P=.51).

CONCLUSIONS - Treatment of DES ISR using DEB or second-generation DES did not differ in terms of late loss at 9-month angiographic follow-up, whereas DES showed better angiographic results regarding minimal MLD and percent diameter stenosis. Both treatment strategies were safe and effective up to 1 year after the procedure.