CBS 2019
CBSMD教育中心
中 文

Rotational Atherectomy

Abstract

Recommended Article

In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens Prevalence, Presentation and Treatment of 'Balloon Undilatable' Chronic Total Occlusions: Insights from a Multicenter US Registry The Hybrid Approach to Chronic Total Occlusion Percutaneous Coronary Intervention: Update From the PROGRESS CTO Registry Chronic Total Occlusion Interventions: Update on Current Tips and Tricks In-Hospital Outcomes of Chronic Total Occlusion Percutaneous Coronary Interventions in Patients With Prior Coronary Artery Bypass Graft Surgery A Meta-Analysis of Contemporary Lesion Modification Strategies During Percutaneous Coronary Intervention in 244,795 Patients From 22 Studies Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Rotational atherectomy in the subadventitial space to allow safe and successful chronic total occlusion recanalization: Pushing the limit further

Clinical Trial2014 May;7(5):510-8.

JOURNAL:JACC Cardiovasc Interv. Article Link

Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II)

Chambers JW, Feldman RL, Himmelstein S et al. Keywords: atherectomy; calcification; cardiovascular intervention; clinical trial

ABSTRACT


OBJECTIVES - The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial evaluated the safety and efficacy of the coronary Orbital Atherectomy System (OAS) to prepare de novo, severely calcified coronary lesions for stent placement.


BACKGROUND - Despite advances in interventional techniques, treatment of calcified coronary lesions remains a challenge. Stent placement in these lesions may result in stent underexpansion, malapposition, and procedural complications.

METHODS - ORBIT II is a prospective, multicenter, nonblinded clinical trial that enrolled 443 consecutive patients with severely calcified coronary lesions at 49 U.S. sites from May 25, 2010, to November 26, 2012. Investigators used the centrifugal action of the OAS diamond-coated crown to modify calcified lesions prior to stent placement.

RESULTS - The pre-procedure mean minimal lumen diameter of 0.5 mm increased to 2.9 mm after the procedure. The primary safety endpoint was 89.6% freedom from 30-day major adverse cardiac events compared with the performance goal of 83%. The primary efficacy endpoint (residual stenosis <50% post-stent without in-hospital major adverse cardiac events) was 88.9% compared with the performance goal of 82%. Stent delivery occurred successfully in 97.7% of cases with <50% stenosis in 98.6% of subjects. Low rates of in-hospital Q-wave myocardial infarction (0.7%), cardiac death (0.2%), and target vessel revascularization (0.7%) were reported.

CONCLUSIONS - The ORBIT II coronary OAS trial met both the primary safety and efficacy endpoints by significant margins. Preparation of severely calcified plaque with the OAS not only helped facilitate stent delivery, but improved both acute and 30-day clinical outcomes compared with the outcomes of historic control subjects in this difficult-to-treat patient population. (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions [ORBIT II]; NCT01092416).

Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.