CBS 2019
CBSMD教育中心
中 文

药物涂层球囊

Abstract

Recommended Article

Prospective, large-scale multicenter trial for the use of drug-coated balloons in coronary lesions: The DCB-only All-Comers Registry Percutaneous coronary intervention with drug-coated balloon-only strategy in stable coronary artery disease and in acute coronary syndromes: An all-comers registry study Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Drug-Coated Balloon for De Novo Coronary Artery Disease: JACC State-of-the-Art Review Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Survival After Coronary Revascularization With Paclitaxel-Coated Balloons

B Scheller, D Vukadinovic, R Jeger et al. Keywords: DCB; paclitaxel; PCI; survival

ABSTRACT


BACKGROUND - Drug-coated balloons (DCBs) are accepted treatment strategies for coronary in-stent restenosis and are under clinical investigation for lesions without prior stent implantation. A recently published meta-analysis suggested an increased risk of death associated with the use of paclitaxel-coated devices in the superficial femoral artery. The reasons are incompletely understood as potential underlying pathomechanisms remain elusive, and no relationship to the administered dose has been documented.

 

OBJECTIVES - The purpose of this analysis was to investigate the available data on survival after coronary intervention with paclitaxel-coated balloons from randomized controlled trials (RCTs).

 

METHODS - PubMed, Web of science, and the Cochrane library database were searched, and a meta-analysis from RCT was performed comparing DCB with non-DCB devices (such as conventional balloon angioplasty, bare-metal stents, or drug-eluting stents) for the treatment of coronary in-stent restenosis or de novo lesions. The primary outcome was all-cause death. The number of patients lost to follow-up was observed at different time points. Risk estimates are reported as risk ratios (RRs) with 95% confidence intervals (CIs).

 

RESULTS - A total of 4,590 patients enrolled in 26 RCTs published between 2006 and 2019 were analyzed. At follow-up of 6 to 12 months, no significant difference in all-cause mortality was found, however, with numerically lower rates after DCB treatment (RR: 0.74; 95% CI: 0.51 to 1.08; p = 0.116). Risk of death at 2 years (n = 1,477, 8 RCTs) was similar between the 2 groups (RR: 0.84; 95% CI: 0.51 to 1.37; p = 0.478). After 3 years of follow-up (n = 1,775, 9 RCTs), all-cause mortality was significantly lower in the DCB group when compared with control treatment (RR: 0.73; 95% CI: 0.53 to 1.00; p = 0.047) with a number needed to treat of 36 to prevent 1 death. A similar reduction was seen in cardiac mortality (RR: 0.53; 95% CI: 0.33 to 0.85; p = 0.009).

 

CONCLUSIONS - In this meta-analysis, the use of paclitaxel DCBs for treatment of coronary artery disease was not associated with increased mortality, as has been suggested for peripheral arteries. On the contrary, use of coronary paclitaxel-coated balloons was associated with a trend toward lower mortality when compared with control treatments.