CBS 2019
CBSMD教育中心
中 文

血流储备分数

Abstract

Recommended Article

Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Coronary Physiology in the Cardiac Catheterization Laboratory Relationship between fractional flow reserve value and the amount of subtended myocardium Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW Coronary CT Angiographic and Flow Reserve-Guided Management of Patients With Stable Ischemic Heart Disease Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease Physiologic Characteristics and Clinical Outcomes of Patients With Discordance Between FFR and iFR

Original ResearchVolume 11, Issue 15, August 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy

D Nakamura, W Wijns, MJ Price et al. Keywords: fractional flow reserve; optical coherence tomography; restenosis; stent expansion

ABSTRACT


OBJECTIVES - This study sought to compare conventional methodology (CM) with a newly described optical coherence tomography (OCT)-derived volumetric stent expansion analysis in terms of fractional flow reserve (FFR)-derived physiology and device-oriented composite endpoints (DoCE).


BACKGROUND - The analysis of coronary stent expansion with intracoronary imaging has used CM that relies on the analysis of selected single cross-sections for several decades. The introduction of OCT with its ability to perform semiautomated volumetric analysis opens opportunities to redefine optimal stent expansion.

METHODS - A total of 291 lesions treated with post-stent OCT and FFR were enrolled. The expansion index was calculated by using a novel volumetric algorithm and was defined as: ([actual lumen area / ideal lumen area] × 100) for each frame of the stented segment. The minimum expansion index (MEI) was defined as the minimum value of expansion index along the entire stented segment. MEI and conventional lumen expansion metrics were compared for the ability to predict post-stent low FFR (<0.90) and DoCE at 1 year.

RESULTS - There was a stronger correlation between MEI and final FFR, compared with CM and final FFR (r = 0.690; p < 0.001) versus (r = 0.165; p = 0.044). MEI was significantly lower in patients with DoCE than those without DoCE (72.18 ± 8.23% vs. 81.48 ± 11.03%; p < 0.001), although stent expansion by CM was similar between patients with and without DoCE (85.05 ± 22.19% and 83.73 ± 17.52%; p = 0.858), respectively.

CONCLUSIONS - OCT analysis of stent expansion with a newly described volumetric method, but not with CM, yielded data that were predictive of both an acute improvement in FFR-derived physiology and DoCE.