CBS 2019
CBSMD教育中心
中 文

Bifurcation Stenting

Abstract

Recommended Article

The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations The Comparison of Clinical Outcomes After Drug-Eluting Balloon and Drug-Eluting Stent Use for Left Main Bifurcation In-Stent Restenosis Treatment of coronary bifurcation lesions: current knowledge and future perspectives Randomized trial of simple versus complex drug-eluting stenting for bifurcation lesions: the British Bifurcation Coronary Study: old, new, and evolving strategies Two-Year Outcomes and Predictors of Target Lesion Revascularization for Non-Left Main Coronary Bifurcation Lesions Following Two-Stent Strategy With 2nd-Generation Drug-Eluting Stents Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Percutaneous coronary intervention for obstructive bifurcation lesions the 14th consensus document from the european bifurcation club Bench testing and coronary artery bifurcations: a consensus document from the European Bifurcation Club

Clinical Case Study2018 Feb 2;13(15):e1812-e1813.

JOURNAL:EuroIntervention. Article Link

Influence of the sequence of proximal optimisation technique and side branch dilation for the opening of jailed struts after coronary bifurcation stenting

Murasato Y, Mori T, Okamura T et al. Keywords: proximal optimisation technique; side branch dilation; jailed struts; coronary bifurcation stenting

ABSTRACT


A 67-year-old man with a 1,1,0 lesion in the left circumflex artery obtuse marginal branch bifurcation (Panel Aa), in which vessel references in the proximal, distal MV and SB were 3.2, 2.6, and 2.8 mm, respectively, underwent zotarolimus-eluting 2.75×12 mm stent (Medtronic, Minneapolis, MN, USA) implantation at 8 atm (Panel Ab). POT was performed with the stent delivery balloon at 12 atm with its distal marker located in the carina to ensure that the stent was well apposed (Panel Ac). A 2.5×4 mm Glider PTCA balloon (TriReme, Pleasanton, CA, USA) was subsequently dilated in the SB ostium (Panel Ad). The procedure was guided with two-dimensional (2D) OCT (St. Jude Medical, St. Paul, MN, USA) and the data were sent to another hospital for 3D reconstruction using dedicated software (INTAGE Realia; CYBERNET, Tokyo, Japan). The 3D image demonstrated GWR into the proximal cell (Panel Ba); however, the protruded struts were folded towards the distal SB after SB dilation (Panel Bb-Bd, Moving image 1, Moving image 2).