A Novel Algorithm for Treating Chronic Total Coronary Artery Occlusion Association of preoperative glucose concentration with myocardial injury and death after non-cardiac surgery (GlucoVISION): a prospective cohort study Discharge Against Medical Advice After Percutaneous Coronary Intervention in the United States Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease Mortality Differences Associated With Treatment Responses in CANTOS and FOURIER: Insights and Implications Frequency, Regional Variation, and Predictors of Undetermined Cause of Death in Cardiometabolic Clinical Trials: A Pooled Analysis of 9259 Deaths in 9 Trials The year in cardiovascular medicine 2020: interventional cardiology Impact of lesion complexity on peri-procedural adverse events and the benefit of potent intravenous platelet adenosine diphosphate receptor inhibition after percutaneous coronary intervention: core laboratory analysis from 10 854 patients from the CHAMPION PHOENIX trial Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Coronary Angiography after Cardiac Arrest without ST-Segment Elevation

Clinical TrialJuly 10, 2018

JOURNAL:JAMA Cardiol. Article Link

Effect of a Home-Based Wearable Continuous ECG Monitoring Patch on Detection of Undiagnosed Atrial Fibrillation The mSToPS Randomized Clinical Trial

SR Steinhubl, J Waalen, AM Edwards et al. Keywords: Atrial Fibrillation; Cardiology; Rhythm Disorders; Mobile Health and Telemedicine

ABSTRACT


IMPORTANCE - Opportunistic screening for atrial fibrillation (AF) is recommended, and improved methods of early identification could allow for the initiation of appropriate therapies to prevent the adverse health outcomes associated with AF.


OBJECTIVE -  To determine the effect of a self-applied wearable electrocardiogram (ECG) patch in detecting AF and the clinical consequences associated with such a detection strategy.

DESIGN, SETTING, and PARTICIPANTS - A direct-to-participant randomized clinical trial and prospective matched observational cohort study were conducted among members of a large national health plan. Recruitment began November 17, 2015, and was completed on October 4, 2016, and 1-year claims-based follow-up concluded in January 2018. For the clinical trial, 2659 individuals were randomized to active home-based monitoring to start immediately or delayed by 4 months. For the observational study, 2 deidentified age-, sex- and CHA2DS2-VASc–matched controls were selected for each actively monitored individual.

INTERVENTIONS - The actively monitored cohort wore a self-applied continuous ECG monitoring patch at home during routine activities for up to 4 weeks, initiated either immediately after enrolling (n = 1364) or delayed for 4 months after enrollment (n = 1291).

MAIN OUTCOMES and MEASURES -  The primary end point was the incidence of a new diagnosis of AF at 4 months among those randomized to immediate monitoring vs delayed monitoring. A secondary end point was new AF diagnosis at 1 year in the combined actively monitored groups vs matched observational controls. Other outcomes included new prescriptions for anticoagulants and health care utilization (outpatient cardiology visits, primary care visits, or AF-related emergency department visits and hospitalizations) at 1 year.

RESULTS -  The randomized groups included 2659 participants (mean [SD] age, 72.4 [7.3] years; 38.6% women), of whom 1738 (65.4%) completed active monitoring. The observational study comprised 5214 (mean [SD] age, 73.7 [7.0] years; 40.5% women; median CHA2DS2-VASc score, 3.0), including 1738 actively monitored individuals from the randomized trial and 3476 matched controls. In the randomized study, new AF was identified by 4 months in 3.9% (53/1366) of the immediate group vs 0.9% (12/1293) in the delayed group (absolute difference, 3.0% [95% CI, 1.8%-4.1%]). At 1 year, AF was newly diagnosed in 109 monitored (6.7 per 100 person-years) and 81 unmonitored (2.6 per 100 person-years; difference, 4.1 [95% CI, 3.9-4.2]) individuals. Active monitoring was associated with increased initiation of anticoagulants (5.7 vs 3.7 per 100 person-years; difference, 2.0 [95% CI, 1.9-2.2]), outpatient cardiology visits (33.5 vs 26.0 per 100 person-years; difference, 7.5 [95% CI, 7.2-7.9), and primary care visits (83.5 vs 82.6 per 100 person-years; difference, 0.9 [95% CI, 0.4-1.5]). There was no difference in AF-related emergency department visits and hospitalizations (1.3 vs 1.4 per 100 person-years; difference, 0.1 [95% CI, −0.1 to 0]).

CONCLUSIONS and RELEVANCE  Among individuals at high risk for AF, immediate monitoring with a home-based wearable ECG sensor patch, compared with delayed monitoring, resulted in a higher rate of AF diagnosis after 4 months. Monitored individuals, compared with nonmonitored controls, had higher rates of AF diagnosis, greater initiation of anticoagulants, but also increased health care resource utilization at 1 year.

TRIAL REGISTRATION -  ClinicalTrials.gov Identifier: NCT02506244