CBS 2019
CBSMD教育中心
English

药物涂层球囊

科研文章

荐读文献

Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis Survival After Coronary Revascularization With Paclitaxel-Coated Balloons Benefits with drug-coated balloon as compared to a conventional revascularization strategy for the treatment of coronary and non-coronary arterial disease: a comprehensive meta-analysis of 45 randomized trials Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis

Original Research2018 Sep 28.[Epub ahead of print]

JOURNAL:Coron Artery Dis. Article Link

Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons

Schröder J, Vogt F, Burgmaier M et al. Keywords: two drug-coated balloons; Long-term clinical outcomes; major adverse cardiac event; in-stent restenosis; Paclitaxel-coated balloon;

ABSTRACT


BACKGROUND - Treatment of in-stent restenosis (ISR) is still a clinical challenge in interventional cardiology. Paclitaxel-coated balloons (PCBs) are an attractive therapeutic option for ISR. There are several different types of PCBs available for percutaneous coronary intervention, but to date, comparative data between different types of PCBs for the treatment of ISR are scarce.


PATIENTS AND METHODS - This single centre, nonrandomized, retrospective study under real-world condition included 194 patients with 194 ISR treated by repeat percutaneous coronary intervention with PCBs. The primary end point was major adverse cardiac events (MACEs), defined as cardiac death, myocardial infarction and need for target lesion revascularization (TLR) at 1 year. Secondary end points were MACE and TLR at long-term follow-up.


RESULTS - Baseline clinical and angiographic parameters were comparable between the two groups. Patients in the iopromide-based PCB and butyryl-tri-hexyl citrate (BTHC)-PCB groups were followed up for 32.2±20.5 and 24.2±13.3 months, respectively (P=0.001). MACEs at 1-year follow-up were 15.0 and 15.8% (P=0.879) for the BTHC-PCB and iopromide-based PCB groups, respectively. TLR, myocardial infarction and cardiac death for BTHC-PCB versus iopromide-based PCB at 1-year follow-up were 9.6 versus 11.8%, P=0.622; 5.3 versus 3.9%, P=0.640; and 5.3 versus 3.9%, P=0.640, respectively. If complete follow-up periods were included in the analysis, BTHC-PCB and iopromide-based PCB had comparable rates of MACE (P=0.835) and TLR (P=0.792).


CONCLUSION - BTHC-PCB and iopromide-based PCB had comparable rates of MACE and TLR for the treatment of ISR at 1-year and long-term follow-up.