CBS 2019
CBSMD教育中心
English

药物涂层球囊

科研文章

荐读文献

Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis Survival After Coronary Revascularization With Paclitaxel-Coated Balloons Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis Benefits with drug-coated balloon as compared to a conventional revascularization strategy for the treatment of coronary and non-coronary arterial disease: a comprehensive meta-analysis of 45 randomized trials

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Survival After Coronary Revascularization With Paclitaxel-Coated Balloons

B Scheller, D Vukadinovic, R Jeger et al. Keywords: DCB; paclitaxel; PCI; survival

ABSTRACT


BACKGROUND - Drug-coated balloons (DCBs) are accepted treatment strategies for coronary in-stent restenosis and are under clinical investigation for lesions without prior stent implantation. A recently published meta-analysis suggested an increased risk of death associated with the use of paclitaxel-coated devices in the superficial femoral artery. The reasons are incompletely understood as potential underlying pathomechanisms remain elusive, and no relationship to the administered dose has been documented.

 

OBJECTIVES - The purpose of this analysis was to investigate the available data on survival after coronary intervention with paclitaxel-coated balloons from randomized controlled trials (RCTs).

 

METHODS - PubMed, Web of science, and the Cochrane library database were searched, and a meta-analysis from RCT was performed comparing DCB with non-DCB devices (such as conventional balloon angioplasty, bare-metal stents, or drug-eluting stents) for the treatment of coronary in-stent restenosis or de novo lesions. The primary outcome was all-cause death. The number of patients lost to follow-up was observed at different time points. Risk estimates are reported as risk ratios (RRs) with 95% confidence intervals (CIs).

 

RESULTS - A total of 4,590 patients enrolled in 26 RCTs published between 2006 and 2019 were analyzed. At follow-up of 6 to 12 months, no significant difference in all-cause mortality was found, however, with numerically lower rates after DCB treatment (RR: 0.74; 95% CI: 0.51 to 1.08; p = 0.116). Risk of death at 2 years (n = 1,477, 8 RCTs) was similar between the 2 groups (RR: 0.84; 95% CI: 0.51 to 1.37; p = 0.478). After 3 years of follow-up (n = 1,775, 9 RCTs), all-cause mortality was significantly lower in the DCB group when compared with control treatment (RR: 0.73; 95% CI: 0.53 to 1.00; p = 0.047) with a number needed to treat of 36 to prevent 1 death. A similar reduction was seen in cardiac mortality (RR: 0.53; 95% CI: 0.33 to 0.85; p = 0.009).

 

CONCLUSIONS - In this meta-analysis, the use of paclitaxel DCBs for treatment of coronary artery disease was not associated with increased mortality, as has been suggested for peripheral arteries. On the contrary, use of coronary paclitaxel-coated balloons was associated with a trend toward lower mortality when compared with control treatments.