CBS 2019
CBSMD教育中心
English

光学相关断层扫描

科研文章

荐读文献

Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study Characteristics of stent thrombosis in bifurcation lesions analysed by optical coherence tomography Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation: The VANISH Trial Coronary Optical Coherence Tomography and Cardiac Magnetic Resonance Imaging to Determine Underlying Causes of Myocardial Infarction With Nonobstructive Coronary Arteries in Women A new optical coherence tomography-based calcium scoring system to predict stent underexpansion Optical coherence tomography-guided percutaneous coronary intervention in ST-segmentelevation myocardial infarction: a prospective propensity-matched cohort of the thrombectomy versus percutaneous coronary intervention alone trial Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention in Patients with Non-ST-Elevation Acute Coronary Syndrome: Results of the Multicenter, Randomized DOCTORS Study (Does Optical Coherence Tomography Optimize Results of Stenting)

Original ResearchApril 2019

JOURNAL:JACC: Cardiovascular Interventions Article Link

Myocardial Blood Flow and Coronary Flow Reserve During 3 Years Following Bioresorbable Vascular Scaffold Versus Metallic Drug-Eluting Stent Implantation: The VANISH Trial

WJ Stuijfzand, SP Schumacher, RS Driessen et al. Keywords: Heart Failure and Cardiomyopathies, Invasive Cardiovascular Angiography and Intervention, Noninvasive Imaging, Vascular Medicine, Interventions and Imaging, Interventions and Vascular Medicine, Angiography, Computed Tomography, Nuclear Imaging

ABSTRACT

OBJECTIVES- The randomized clinical VANISH (Impact of Vascular Reparative Therapy on Vasomotor Function and Myocardial Perfusion: A Randomized [15O]H2O PET/CT Study) trial was conducted to assess quantitative myocardial blood flow (MBF) during resting, hyperemia, and cold pressor testing (CPT) with positron emission tomographic perfusion imaging after the implantation of a bioresorbable everolimus-eluting scaffold compared with a drug-eluting stent.

 

BACKGROUND- Long-term resorption of the bioresorbable everolimus-eluting scaffold reinstates normal vessel geometry, allowing natural regeneration of the newly formed endothelium with revival of vasomotor function.

 

METHODS- Sixty patients (18 to 65 years of age) with single-vessel disease and type A or B1 lesions were randomized in a 1-to-1 fashion. Approximately 1 month, 1 year, and 3 years after device implantation, patients underwent [15O]H2O cardiac positron emission tomography. The primary endpoint was the interaction of device type and evolution over time of hyperemic MBF, coronary flow reserve, or CPT reserve. At 3-year follow-up, control invasive coronary angiography with optical coherence tomography was performed.

 

RESULTS - Fifty-nine (98%), 56 (93%), and 51 (85%) patients successfully completed 1-month, 1-year, and 3-year follow-up positron emission tomography, respectively, and no culprit vessel events were registered during follow-up time. The primary study endpoint (i.e., interaction between device type and time) was nonsignificant for hyperemic MBF, CPT reserve, and coronary flow reserve (p > 0.05 for all). In all patients, hyperemic MBF decreased from 1 to 3 years (p = 0.02), while coronary flow reserve was lower at 3-year follow-up compared with 1-month and 1-year follow-up (p = 0.03 for both). After 3 years, percentage area stenosis measured with optical coherence tomography was higher within the bioresorbable everolimus-eluting scaffold compared with the drug-eluting stent (p = 0.03).

 

CONCLUSIONS- The hypothesized beneficial effects of scaffold resorption did not translate to improved MBF during maximal hyperemia or endothelium-dependent vasodilation by CPT.