Intracoronary Optical Coherence Tomography 2018: Current Status and Future Directions Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Combining IVUS and Optical Coherence Tomography for More Accurate Coronary Cap Thickness Quantification and Stress/Strain Calculations: A Patient-Specific Three-Dimensional Fluid-Structure Interaction Modeling Approach Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention) Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study Intracoronary Optical Coherence Tomography-Derived Virtual Fractional Flow Reserve for the Assessment of Coronary Artery Disease Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry

Clinical Trial2018 Apr 6;13(18):e2174-e2181.

JOURNAL:EuroIntervention. Article Link

Characteristics of stent thrombosis in bifurcation lesions analysed by optical coherence tomography

Bechiri MY, Souteyrand G, Lefèvre T et al. Keywords: bifurcation; OCT; stent thrombosis; late ST; VLST; ACS/NSTE-ACS;

ABSTRACT


AIMSThis work aimed to investigate a cohort of patients presenting with stent thrombosis (ST) explored by optical coherence tomography (OCT) to identify the underlying mechanical abnormalities in case of bifurcation lesions.


METHODS AND RESULTSThe PESTO study was a prospective national registry involving 29 French catheterisation facilities. Patients with acute coronary syndromes were prospectively screened for presence of definite ST and analysed by OCT after culprit lesion reopening. The cohort involved 120 subjects, including 21 patients (17.5% of the global PESTO group; median age: 62.6 yrs; 76% male) with bifurcation lesions. The clinical presentation was acute or subacute ST in 34%, late ST in 5% and very late ST in 62% of the patients. The main underlying mechanisms were strut malapposition in 33%, stent underexpansion in 19% and isolated strut uncoverage in 19% of the cases. The proximal main branch was involved in 71%, distal main branch in 52% and jailed side branch in 5% of the patients.

CONCLUSIONSIn this cohort, bifurcation lesions represented a limited number of all ST cases. Different sections of the bifurcation could be involved. Although the underlying mechanisms were various, strut malapposition was the most frequently observed cause.