CBS 2019
CBSMD教育中心
English

经导管主动脉瓣置换

科研文章

荐读文献

Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis Increased Risk of Valvular Heart Disease in Systemic Sclerosis: An Underrecognized Cardiac Complication Timing of intervention in asymptomatic patients with valvular heart disease The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Meta-Analysis of Effectiveness and Safety of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Low-to-Intermediate Surgical Risk Cohort Precision Medicine in TAVR: How to Select the Right Device for the Right Patient

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation

A Krishnaswamy, Y Sammour, A Mangieri et al. Keywords: atrial pacing; electrophysiology study; permanent pacemaker implantation;TAVR

ABSTRACT

OBJECTIVES - The aim of this study was to determine the utility of rapid atrial pacing immediately after transcatheter aortic valve replacement (TAVR) to predict the need for permanent pacemaker implantation (PPI).

 

BACKGROUND - Risk stratification for patients without high-grade atrioventricular block (AVB) after TAVR is imprecise and based on anatomic considerations, electrocardiographic characteristics, and clinical suspicion. A more reliable assessment is necessary to minimize inpatient rhythm monitoring and/or reduce unnecessary PPI.

 

METHODS - Consecutive patients undergoing TAVR at 2 centers were included. After valve implantation in patients without pacemakers who did not have complete heart block or atrial fibrillation, the temporary pacemaker was withdrawn from the right ventricle and placed in the right atrium. Rapid atrial pacing was performed from 70 to 120 beats/min, and patients were assessed for the development of Wenckebach AVB. Patients were then followed for clinical outcomes, including PPI.

 

RESULTS - A total of 284 patients were included. Of these, 130 (45.8%) developed Wenckebach AVB. There was a higher rate of PPI within 30 days of TAVR among the patients who developed Wenckebach AVB (13.1% vs. 1.3%; p < 0.001), with a negative predictive value for PPI in the group without Wenckebach AVB of 98.7%. A greater percentage of patients receiving self-expanding valves required PPI than those receiving a balloon-expandable valves (15.9% vs. 3.7%; p = 0.001), though these rates were still relatively low among patients who did not develop Wenckebach AVB (2.9% and 0.8%).

 

CONCLUSIONS - Atrial pacing post-TAVR is easily performed and can help identify patients who may benefit from extended rhythm monitoring. Patients who did not develop pacing-induced Wenckebach AVB demonstrated an extremely low likelihood of PPI.