CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Summary of Updated Recommendations for Primary Prevention of Cardiovascular Disease in Women: JACC State-of-the-Art Review Heart Failure With Recovered Left Ventricular Ejection Fraction: JACC Scientific Expert Panel Prior Balloon Valvuloplasty Versus Direct Transcatheter Aortic Valve Replacement: Results From the DIRECTAVI Trial Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis Six-month versus 12-month dual antiplatelet therapy after implantation of drug-eluting stents: the Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting (EXCELLENT) randomized, multicenter study Predictors and Clinical Outcomes of Next-Day Discharge After Minimalist Transfemoral Transcatheter Aortic Valve Replacement Delirium After TAVR: Crosspassing the Limit of Resilience

Review Article2017 Apr, Epub 2017 Mar 22

JOURNAL:Anatol J Cardiol. Article Link

The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients

Fan ZG, Gao XF, Tian NL et al. Keywords: intravascular ultrasound, drug-eluting stent, complex lesions, meta-analysis

ABSTRACT


OBJECTIVE - The effects of intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation in patients with complex coronary artery lesions remains to be controversial. This study sought to evaluate the outcomes of IVUS guidance in these patients.


METHODS- The EMBASE, Medline, and other internet sources were searched for relevant articles. The primary endpoint was major adverse cardiac events (MACE), including all-cause mortality, myocardial infarction (MI), and target-vessel revascularization (TVR). The incidence of definite/probable stent thrombosis (ST) was analyzed as the safety endpoint.


RESULTS- Fifteen clinical trials involving 8.084 patients were analyzed. MACE risk was significantly decreased following IVUS-guided DES implantation compared with coronary angiography (CAG) guidance (odds ratio [OR] 0.63, 95% confidence intervals [CI]: 0.53-0.73, p<0.001), which might mainly result from the lower all-cause mortality risk (OR 0.52, 95% CI: 0.40-0.67, p<0.001), MI (OR 0.70, 95% CI: 0.56-0.86, p=0.001), and TVR (OR 0.53, 95% CI: 0.40-0.70, p<0.001). The subgroup analyses indicated better outcomes of IVUS guidance in DES implantation for these patients with left main disease or bifurcation lesions.


CONCLUSION- IVUS guidance in DES implantation is associated with a significant reduction in MACE risk in patients with complex lesions, particularly those with left main disease or bifurcation lesions. More large and powerful randomized trials are still warranted to guide stenting decision making.