Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention in Patients with Non-ST-Elevation Acute Coronary Syndrome: Results of the Multicenter, Randomized DOCTORS Study (Does Optical Coherence Tomography Optimize Results of Stenting) Optical coherence tomography-guided percutaneous coronary intervention in ST-segmentelevation myocardial infarction: a prospective propensity-matched cohort of the thrombectomy versus percutaneous coronary intervention alone trial The Natural History of Nonculprit Lesions in STEMI: An FFR Substudy of the Compare-Acute Trial Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Pulmonary Artery Denervation: A New, Long-Awaited Interventional Treatment for Combined Pre- and Post-Capillary Pulmonary Hypertension? Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial

Review Article2017 Apr, Epub 2017 Mar 22

JOURNAL:Anatol J Cardiol. Article Link

The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients

Fan ZG, Gao XF, Tian NL et al. Keywords: intravascular ultrasound, drug-eluting stent, complex lesions, meta-analysis

ABSTRACT


OBJECTIVE - The effects of intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation in patients with complex coronary artery lesions remains to be controversial. This study sought to evaluate the outcomes of IVUS guidance in these patients.


METHODS- The EMBASE, Medline, and other internet sources were searched for relevant articles. The primary endpoint was major adverse cardiac events (MACE), including all-cause mortality, myocardial infarction (MI), and target-vessel revascularization (TVR). The incidence of definite/probable stent thrombosis (ST) was analyzed as the safety endpoint.


RESULTS- Fifteen clinical trials involving 8.084 patients were analyzed. MACE risk was significantly decreased following IVUS-guided DES implantation compared with coronary angiography (CAG) guidance (odds ratio [OR] 0.63, 95% confidence intervals [CI]: 0.53-0.73, p<0.001), which might mainly result from the lower all-cause mortality risk (OR 0.52, 95% CI: 0.40-0.67, p<0.001), MI (OR 0.70, 95% CI: 0.56-0.86, p=0.001), and TVR (OR 0.53, 95% CI: 0.40-0.70, p<0.001). The subgroup analyses indicated better outcomes of IVUS guidance in DES implantation for these patients with left main disease or bifurcation lesions.


CONCLUSION- IVUS guidance in DES implantation is associated with a significant reduction in MACE risk in patients with complex lesions, particularly those with left main disease or bifurcation lesions. More large and powerful randomized trials are still warranted to guide stenting decision making.