CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY Infective Endocarditis After Transcatheter Aortic Valve Replacement Ascending Aortic Length and Risk of Aortic Adverse Events: The Neglected Dimension New-onset atrial fibrillation after PCI and CABG for left main disease: insights from the EXCEL trial and additional studies Evolving concepts in the management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes 2019 AHA/ACC Clinical Performance and Quality Measures for Adults With High Blood Pressure: A Report of the American College of Cardiology/American Heart Association Task Force on Performance Measures Treatment and prevention of lipoprotein(a)-mediated cardiovascular disease: the emerging potential of RNA interference therapeutics Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Differences between the left main and other bifurcations

Review ArticleJuly 27, 2017

JOURNAL:Oncotarget. Article Link

Intravascular ultrasound guidance in drug-eluting stents implantation: a meta-analysis and trial sequential analysis of randomized controlled trials

Qian C, Feng H, Cao J et al. Keywords: intravascular ultrasound, drug-eluting stents, meta-analysis, trial sequential analysis, randomized controlled trials

ABSTRACT

OBJECTIVES - Previous evidence suggested that intravascular ultrasound (IVUS) guidance could improve outcomes after drug-eluting stents (DES) placement, largely driven by data from observational studies. We, therefore, performed a meta-analysis and trial sequential analysis of randomized controlled trials to overcome this limitation.


RESULTS -  The retrieval process yielded 7 RCTs with 3,192 patients. Compared to the angiography guidance, IVUS-guided DES implantation was associated with a significant reduction in the major adverse cardiac events (MACE) (OR 0.60, 95% CI 0.46-0.78; P < 0.001), target vessel revascularization (OR 0.60, 95% CI 0.40-0.91; P = 0.02) and target lesion revascularization (OR 0.60, 95% CI 0.42-0.85; P = 0.004). IVUS and conventional angiography guidance showed similar incidence of stent thrombosis (ST) (OR 0.56, 95% CI 0.25-1.23; P = 0.15), cardiac death (OR 0.47, 95% CI 0.19-1.15; P = 0.10) and myocardial infarction (OR 0.85, 95% CI 0.45-1.61; P = 0.62). Trial sequential analysis revealed a definite reduction in MACE with IVUS guidance without solid evidence for ST.


MATERIALS AND METHODS - A systematical literature search was performed in the databases of PubMed, the Cochrane Library and ClinicalTrials.gov, complemented with reference screening from relevant articles. Primary endpoints were MACE and ST.


CONCLUSIONS - IVUS-guided DES implantation is associated with a lower risk of MACE and revascularization without conclusive benefits for ST.