Bosentan therapy in patients with Eisenmenger syndrome: a multicenter, double-blind, randomized, placebo-controlled study Impact of myocardial supply area on the transstenotic hemodynamics as determined by fractional flow reserve Intravascular optical coherence tomography Optical coherence tomography and C-reactive protein in risk stratification of acute coronary syndromes High-Resolution Cardiac Magnetic Resonance Imaging Techniques for the Identification of Coronary Microvascular Dysfunction Long-term secondary prevention of cardiovascular disease with a Mediterranean diet and a low-fat diet (CORDIOPREV): a randomised controlled trial Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies Active and Passive Vaccination for Pulmonary Arterial Hypertension: A Novel Therapeutic Paradigm Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction Asia Pacific Consensus Document on Coronary Bifurcation Interventions

Original Research2006 Jun;27(11):1305-10.

JOURNAL:Eur Heart J. Article Link

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

Hong MK, Mintz GS, Lee CW et al. Keywords: post-procedural final minimum stent area; IVUS; sirolimus-eluting stent; angiographic restenosis; stent length

ABSTRACT

 

AIMS - In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation.

 

METHODS AND RESULTS - SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR)=0.586, 95% confidence interval (CI) 0.387-0.888, P=0.012] and IVUS-measured stent length (OR=1.029, 95% CI 1.002-1.056, P=0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm2 and 40 mm, respectively. Lesions with final minimum stent area<5.5 mm2 and stent length>40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P<0.001 compared with other groups.

 

CONCLUSION - Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area<5.5 mm2 and stent length>40 mm.