CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical Outcomes Following Coronary Bifurcation PCI Techniques: A Systematic Review and Network Meta-Analysis Comprising 5,711 Patients Coronary Flow Reserve in the Instantaneous Wave-Free Ratio/Fractional Flow Reserve Era: Too Valuable to Be Neglected Noninvasive Screening for Pulmonary Hypertension by Exercise Testing in Congenital Heart Disease Updated clinical classification of pulmonary hypertension Anatomical and Functional Computed Tomography for Diagnosing Hemodynamically Significant Coronary Artery Disease: A Meta-Analysis Lesion-Specific and Vessel-Related Determinants of Fractional Flow Reserve Beyond Coronary Artery Stenosis Effect of low-density lipoprotein cholesterol on the geometry of coronary bifurcation lesions and clinical outcomes of coronary interventions in the J-REVERSE registry Three-Year Outcomes of the DKCRUSH-V Trial Comparing DK Crush With Provisional Stenting for Left Main Bifurcation Lesions Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques

Original Research2006 Jun;27(11):1305-10.

JOURNAL:Eur Heart J. Article Link

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

Hong MK, Mintz GS, Lee CW et al. Keywords: post-procedural final minimum stent area; IVUS; sirolimus-eluting stent; angiographic restenosis; stent length

ABSTRACT

 

AIMS - In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation.

 

METHODS AND RESULTS - SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR)=0.586, 95% confidence interval (CI) 0.387-0.888, P=0.012] and IVUS-measured stent length (OR=1.029, 95% CI 1.002-1.056, P=0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm2 and 40 mm, respectively. Lesions with final minimum stent area<5.5 mm2 and stent length>40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P<0.001 compared with other groups.

 

CONCLUSION - Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area<5.5 mm2 and stent length>40 mm.