CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure The year in cardiovascular medicine 2020: heart failure and cardiomyopathies Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure Unexpectedly Low Natriuretic Peptide Levels in Patients With Heart Failure A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries

Original Research2018 Oct 8. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Self-expandable sirolimus-eluting stents compared to second-generation drug-eluting stents for the treatment of the left main: A propensity score analysis from the SPARTA and the FAILS-2 registries

Montefusco A, D'Ascenzo F, Gili S et al. Keywords: percutaneous coronary intervention; second-generation drug-eluting stent; self-expandable stent; unprotected left main

ABSTRACT


OBJECTIVES - To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM).


BACKGROUND - SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.


METHODS - Patients from the multicenter SPARTA (clinicaltrials.gov -  NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.


RESULTS - Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.


CONCLUSION - SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.

 

© 2018 Wiley Periodicals, Inc.