CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report Intravascular ultrasound enhances the safety of rotational atherectomy Procedural Success and Outcomes With Increasing Use of Enabling Strategies for Chronic Total Occlusion Intervention Pulmonary hypertension is associated with an increased incidence of NAFLD: A retrospective cohort study of 18,910 patients North American Expert Review of Rotational Atherectomy The Regulation of Pulmonary Vascular Tone by Neuropeptides and the Implications for Pulmonary Hypertension Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation Trends in Usage and Clinical Outcomes of Coronary Atherectomy: A Report From the National Cardiovascular Data Registry CathPCI Registry Clinical Characteristics and Long-Term Outcomes of Rotational Atherectomy-J2T Multicenter Registry

Clinical TrialOctober 2017, Volume 10, Issue 10

JOURNAL:Circ Cardiovasc Interv. Article Link

Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions

Hakim D, Chatterjee A, Leesar MA et al. Keywords: bifurcation lesions; fractional flow reserve; intravascular ultrasound; proximal optimization technique

ABSTRACT


BACKGROUND - Bench models of coronary bifurcation lesions demonstrated that the proximal optimization technique (POT) expanded the stent and opened the side branch (SB). We investigated the role of POT guided by intravascular ultrasound on the main vessel (MV) stent expansion and SB fractional flow reserve (FFR) in patients with coronary bifurcation lesion.


METHODS AND RESULTS - In 40 patients with coronary bifurcation lesion, 120 intravascular ultrasound examinations of the MV were performed at baseline, after MV stenting, and POT followed by 95 FFR measurements of the SB. In the proximal stent segment, stent volume index and minimum stent area were larger after POT versus MV stenting (9.2±3.4 versus 7.40±2.0 mm3/mm and 7.65±1.8 versus 6.38±1.7 mm2, respectively; P<0.01). In the bifurcation segment, minimum stent area was larger after POT versus MV stenting (6.45±2.1 versus 5.9±2.0 mm2, respectively; P<0.05). POT expanded the stent symmetrically. After POT, SB FFR was <0.75 in 12 patients (30%), which improved to >0.75 after SB dilation or SB stenting+final POT. SB FFR was significantly higher after POT+SB dilation or SB stenting+final POT versus after MV stenting and POT.


CONCLUSIONS - This is the first study of POT guided by intravascular ultrasound in patients with coronary bifurcation lesion, demonstrating that POT symmetrically expanded the proximal and bifurcation segments of the stent. After POT, SB FFR was <0.75 in a third of patients, which improved to >0.75 after SB dilation or SB stenting+final POT.