CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

MITRA-FR vs. COAPT: Lessons from two trials with diametrically opposed results Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study Current Status and Future Prospects of Transcatheter Mitral Valve Replacement: JACC State-of-the-Art Review The management of secondary mitral regurgitation in patients with heart failure: a joint position statement from the Heart Failure Association (HFA), European Association of Cardiovascular Imaging (EACVI), European Heart Rhythm Association (EHRA), and European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the ESC Prospective Evaluation of Transseptal TMVR for Failed Surgical Bioprostheses: MITRAL Trial Valve-in-Valve Arm 1-Year Outcomes 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Systematic Review and Network Meta‐Analysis Comparing Bifurcation Techniques for Percutaneous Coronary Intervention Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure

Original Research2018 Apr;33(2):146-153.

JOURNAL:Acta Cardiol Sin. Article Link

Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions

Nomura T, Kikai M, Hori Y et al. Keywords: bifurcation; dual-lumen microcatheter; reverse wire technique

ABSTRACT


In practical settings of percutaneous coronary intervention (PCI), we sometimes encounter difficulty in introducing a guidewire (GW) to the markedly angulated side branch (SB), and the reverse wire technique is considered as a last resort to overcome such a situation. We analyzed 12 cases that underwent PCI with dual-lumen microcatheter-facilitated reverse wire technique between January 2013 and July 2016. We retrospectively investigated the lesion's characteristics and the details of the PCI procedures, and discussed tips about the use of this technique. The SB that exhibits both a smaller take-off angle and a larger carina angle is considered to be the most suitable candidate for this technique. The first step of this technique involves the delivery of the reverse wire system to the target bifurcation. However, most cases exhibit significant stenosis proximal to the bifurcation, which often hampers the delivery of the reverse wire system. Because the sharply curved reverse wire system is easier to pass the stenosis as compared to the roundly curved system, we recommend a sharp curve should be adopted for this technique. On the other hand, it is sure that device delivery is much easier on the GW with a round curve as compared to that with a sharp curve. Therefore, it is important to modify the details of this procedure on a case-by-case basis according to the lesion's characteristics.