Optical Coherence Tomography-Guided Percutaneous Coronary Intervention in ST-Segment-Elevation Myocardial Infarction: A Prospective Propensity-Matched Cohort of the Thrombectomy Versus Percutaneous Coronary Intervention Alone Trial Exercise unmasks distinct pathophysiologic features in heart failure with preserved ejection fraction and pulmonary vascular disease Left main coronary artery compression in pulmonary hypertension Rotational Atherectomy in acute STEMI with heavily calcified culprit lesion is a rule breaking solution Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis Difference in basic concept of coronary bifurcation intervention between Korea and Japan. Insight from questionnaire in experts of Korean and Japanese bifurcation clubs Long-term clinical outcome after fractional flow reserve-guided treatment in patients with angiographically equivocal left main coronary artery stenosis Sildenafil added to pirfenidone in patients with advanced idiopathic pulmonary fibrosis and risk of pulmonary hypertension: A Phase IIb, randomised, double-blind, placebo-controlled study - Rationale and study design Levosimendan Improves Hemodynamics and Exercise Tolerance in PH-HFpEF: Results of the Randomized Placebo-Controlled HELP Trial A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial

Clinical TrialAugust 2017, Volume 10, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation

Piroth Z, Toth GG, De Bruyne B et al. Keywords: acute coronary syndromedrug-eluting stenthospitalizationmyocardial infarctionpercutaneous coronary intervention

ABSTRACT


Background The predictive value of fractional flow reserve (FFR) measured immediately after percutaneous coronary intervention (PCI) with drug-eluting stent placement has not been prospectively investigated. We investigated the potential of post-PCI FFR measurements to predict clinical outcome in patients from FAME 1 and 2 trials (Fractional Flow Reserve or Angiography for Multivessel Evaluation).


Methods and Results All patients of FAME 1 and FAME 2 who had post-PCI FFR measurement were included. The primary outcome was vessel-oriented composite end point at 2 years, defined as vessel-related cardiovascular death, vessel-related spontaneous myocardial infarction, and ischemia-driven target vessel revascularization. Eight hundred thirty-eight vessels in 639 patients were analyzed. Baseline FFR values did not differ between vessels with versus without vessel-oriented composite end point (0.66±0.11 versus 0.63±0.14, respectively; P=0.207). Post-PCI FFR was significantly lower in vessels with vessel-oriented composite end point (0.88±0.06 versus 0.90±0.06, respectively; P=0.019). Comparing the 2-year outcome of lower and upper tertiles of post-PCI FFR significant difference was found favoring upper tertile in terms of overall vessel-oriented composite end point (9.2% versus 3.8%, respectively; hazard ratio, 1.46; 95% confidence interval, 1.02–2.08; P=0.037) and target vessel revascularization (7.0% versus 2.4%, respectively; hazard ratio, 1.59; 95% confidence interval, 1.03–2.46; P=0.037). When adjusted to sex, hypertension, diabetes mellitus, target vessel, serial stenosis, and baseline percentage diameter stenosis, a strong trend was preserved in terms of target vessel revascularization (harzard ratio, 1.55; 95% confidence interval, 0.97–2.46; P=0.066), favoring the upper tertile. Post-PCI FFR of 0.92 was found to have the highest diagnostic accuracy; however, the positive likelihood ratio remained low (<1.4).