CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

TAVI Represents an Anti-Inflammatory Therapy via Reduction of Shear Stress Induced, Piezo-1-Mediated Monocyte Activation Treatment Effects of Pulmonary Artery Denervation for Pulmonary Arterial Hypertension Stratified by REVEAL Risk Score: Results from PADN-CFDA Trial Hemodynamic, Functional, and Clinical Responses to Pulmonary Artery Denervation in Patients With Pulmonary Arterial Hypertension of Different Causes 3-Year Outcomes After 2-Stent With Provisional Stenting for Complex Bifurcation Lesions Defined by DEFINITION Criteria Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion: Insights From the NCDR LAAO Registry Half-Dose Direct Oral Anticoagulation Versus Standard Antithrombotic Therapy After Left Atrial Appendage Occlusion Haemodynamic definitions and updated clinical classification of pulmonary hypertension A Score to Assess Mortality After Percutaneous Mitral Valve Repair Defining cardiovascular toxicities of cancer therapies: an International Cardio-Oncology Society (IC-OS) consensus statement Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients

January 2019

JOURNAL:JACC: Clinical Electrophysiology Article Link

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

A Masri, AM Altibi, S Erqou et al. Keywords: death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator

ABSTRACT

OBJECTIVES - This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD).


BACKGROUND - Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only.


METHODS - We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Lairds method.


RESULTS - Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I2 = 94%).


CONCLUSIONS - The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention.