CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical epidemiology of heart failure with preserved ejection fraction (HFpEF) in comparatively young hospitalized patients Non-obstructive High-Risk Plaques Increase the Risk of Future Culprit Lesions Comparable to Obstructive Plaques Without High-Risk Features: The ICONIC Study Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Cost-Effectiveness of Different Durations of Dual-Antiplatelet Use After Percutaneous Coronary Intervention Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies In acute HF and iron deficiency, IV ferric carboxymaltose reduced HF hospitalizations, but not CV death, at 1 y 中国心力衰竭诊断和治疗指南2018

January 2019

JOURNAL:JACC: Clinical Electrophysiology Article Link

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

A Masri, AM Altibi, S Erqou et al. Keywords: death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator

ABSTRACT

OBJECTIVES - This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD).


BACKGROUND - Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only.


METHODS - We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Lairds method.


RESULTS - Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I2 = 94%).


CONCLUSIONS - The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention.