CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Thrombotic Versus Bleeding Risk After Transcatheter Aortic Valve Replacement: JACC Review Topic of the Week The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Coronary calcium as a predictor of coronary events in four racial or ethnic groups Association Between Depressive Symptoms and Incident Cardiovascular Diseases Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis Osteoarthritis risk is reduced after treatment with ticagrelor compared to clopidogrel: a propensity score matching analysis Second vs. First generation drug eluting stents in multiple vessel disease and left main stenosis: Two-year follow-up of the observational, prospective, controlled, and multicenter ERACI IV registry Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Long-term results after PCI of unprotected distal left main coronary artery stenosis: the Bifurcations Bad Krozingen (BBK)-Left Main Registry Impact of myocardial fibrosis on left ventricular remodelling, recovery, and outcome after transcatheter aortic valve implantation in different haemodynamic subtypes of severe aortic stenosis

Original Research2019 Jul 20;394(10194):230-239.

JOURNAL:Lancet. Article Link

Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial

Rissanen TT, Uskela S, DEBUT trial investigators. Keywords: drug-coated balloons vs bare-metal stents; superiorty; non-inferiority;

ABSTRACT


BACKGROUND - The optimal technique of percutaneous coronary intervention in patients at high bleeding risk is not known. The hypothesis of the DEBUT trial was that percutaneous coronary intervention with drug-coated balloons is non-inferior to percutaneous coronary intervention with bare-metal stents for this population.


METHODS - The DEBUT trial is a randomised, single-blind non-inferiority trial done at five sites in Finland. Patients were eligible if they had an ischaemic de-novo lesion in a coronary artery or bypass graft that could be treated with drug-coated balloons, at least one risk factor for bleeding, and a reference vessel diameter of 2·5-4·0 mm. Those with myocardial infarction with ST-elevation, bifurcation lesions needing a two-stent technique, in-stent restenosis, and flow-limiting dissection or substantial recoil (>30%) of the target lesion after predilation were excluded. After successful predilation of the target lesion, patients were randomly assigned (1:1), by use of a computer-generated random sequence, to percutaneous coronary intervention with a balloon coated with paclitaxel and iopromide or a bare-metal stent. The primary outcome was major adverse cardiac events at 9 months. Non-inferiority was shown if the absolute risk difference was no more than 3%. All prespecified analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01781546.


FINDINGS - Between May 22, 2013, and Jan 16, 2017, 220 patients were recruited for the study and 208 patients were assigned to percutaneous coronary intervention with drug-coated balloon (n=102) or bare metal stent (n=106). At 9 months, major adverse cardiac events had occurred in one patient (1%) in the drug-coated balloon group and in 15 patients (14%) in the bare-metal stent group (absolute risk difference -13·2 percentage points [95% CI -6·2 to -21·1], risk ratio 0·07 [95% CI 0·01 to 0·52]; p<0·00001 for non-inferiority and p=0·00034 for superiority). Two definitive stent thrombosis events occurred in the bare metal stent group but no acute vessel closures in the drug-coated balloon group.


INTERPRETATIONS - Percutaneous coronary intervention with drug-coated balloon was superior to bare-metal stents in patients at bleeding risk. The drug-coated balloon-only coronary intervention is a novel strategy to treat this difficult patient population. Comparison of this approach to the new generation drug-eluting stents is warranted in the future.


FUNDING - B Braun Medical AG, AstraZeneca, and Competitive State Research Funding of the Kuopio University Hospital Catchment Area.

 

Copyright © 2019 Elsevier Ltd. All rights reserved.