CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical Outcome of Double Kissing Crush Versus Provisional Stenting of Coronary Artery Bifurcation Lesions: The 5-Year Follow-Up Results From a Randomized and Multicenter DKCRUSH-II Study (Randomized Study on Double Kissing Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions) Incidence of Adverse Events at 3 Months Versus at 12 Months After Dual Antiplatelet Therapy Cessation in Patients Treated With Thin Stents With Unprotected Left Main or Coronary Bifurcations Chronic thromboembolic pulmonary hypertension Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials Uncovered Culprit Plaque Ruptures in Patients With ST-Segment Elevation Myocardial Infarction Assessed by Optical Coherence Tomography and Intravascular Ultrasound With iMap Comparison of Coronary Intimal Plaques by Optical Coherence Tomography in Arteries With Versus Without Internal Running Vasa Vasorum Covering our tracks – optical coherence tomography to assess vascular healing Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study Elaborately Engineering a Self-Indicating Dual-Drug Nanoassembly for Site-Specific Photothermal-Potentiated Thrombus Penetration and Thrombolysis

Clinical TrialSeptember 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong, GS Mintz, the IVUS-XPL Investigators. Keywords: IVUS guidance superior to angiography guidance; MACE; long-term follow-up; long lesions

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

 

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL trial. It is not known, however, whether this effect is sustained for long-term follow-up.

 

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28mm) to receive IVUS- (n=700) or angiography-guided (n=700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. Primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

 

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS-guidance and in 70 patients (10.7%) receiving angiography-guidance (hazard ratio [HR]=0.50, 95% confidence interval [CI]=0.34−0.75, P=0.001). The difference was mainly driven by a lower risk of target lesion revascularization (31 [4.8%] vs. 55 [8.4%], HR=0.54; 95% CI=0.33−0.89, P=0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS-guidance and in 31 patients (5.2%) receiving angiography-guidance (HR=0.53, 95% CI=0.29-0.95, P=0.031).

 

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years’ post-implantation.