CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Haemodynamic definitions and updated clinical classification of pulmonary hypertension Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study Role of endothelial dysfunction in determining angina after percutaneous coronary intervention: Learning from pathophysiology to optimize treatment Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Role of local coronary blood flow patterns and shear stress on the development of microvascular and epicardial endothelial dysfunction and coronary plaque Ticagrelor alone versus ticagrelor plus aspirin from month 1 to month 12 after percutaneous coronary intervention in patients with acute coronary syndromes (ULTIMATE-DAPT): a randomised, placebo-controlled, double-blind clinical trial Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion: Insights From the NCDR LAAO Registry De-escalating Dual Antiplatelet Therapy to Ticagrelor Monotherapy in Acute Coronary Syndrome : A Systematic Review and Individual Patient Data Meta-analysis of Randomized Clinical Trials Half-Dose Direct Oral Anticoagulation Versus Standard Antithrombotic Therapy After Left Atrial Appendage Occlusion A Score to Assess Mortality After Percutaneous Mitral Valve Repair

Clinical TrialSeptember 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong, GS Mintz, the IVUS-XPL Investigators. Keywords: IVUS guidance superior to angiography guidance; MACE; long-term follow-up; long lesions

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

 

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL trial. It is not known, however, whether this effect is sustained for long-term follow-up.

 

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28mm) to receive IVUS- (n=700) or angiography-guided (n=700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. Primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

 

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS-guidance and in 70 patients (10.7%) receiving angiography-guidance (hazard ratio [HR]=0.50, 95% confidence interval [CI]=0.34−0.75, P=0.001). The difference was mainly driven by a lower risk of target lesion revascularization (31 [4.8%] vs. 55 [8.4%], HR=0.54; 95% CI=0.33−0.89, P=0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS-guidance and in 31 patients (5.2%) receiving angiography-guidance (HR=0.53, 95% CI=0.29-0.95, P=0.031).

 

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years’ post-implantation.