CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Classic crush and DK crush stenting techniques Short Sleep Duration, Obstructive Sleep Apnea, Shiftwork, and the Risk of Adverse Cardiovascular Events in Patients After an Acute Coronary Syndrome Restenosis, Stent Thrombosis, and Bleeding Complications - Navigating Between Scylla and Charybdis Complete Revascularization During Primary Percutaneous Coronary Intervention Reduces Death and Myocardial Infarction in Patients With Multivessel Disease-Meta-Analysis and Meta-Regression of Randomized Trials Stent Thrombosis Risk Over Time on the Basis of Clinical Presentation and Platelet Reactivity: Analysis From ADAPT-DES Evaluation and Management of Nonculprit Lesions in STEMI Major trials in coronary intervention from 2018 In-Hospital Coronary Revascularization Rates and Post-Discharge Mortality Risk in Non–ST-Segment Elevation Acute Coronary Syndrome An EAPCI Expert Consensus Document on Ischaemia with Non-Obstructive Coronary Arteries in Collaboration with European Society of Cardiology Working Group on Coronary Pathophysiology & Microcirculation Endorsed by Coronary Vasomotor Disorders International Study Group Ticagrelor versus Clopidogrel in Patients with STEMI Treated with Fibrinolytic Therapy: TREAT Trial

Clinical TrialSeptember 2019

JOURNAL:JACC Cardiovasc Interv. Article Link

Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial

SJ Hong, GS Mintz, the IVUS-XPL Investigators. Keywords: IVUS guidance superior to angiography guidance; MACE; long-term follow-up; long lesions

ABSTRACT


OBJECTIVES - The goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.

 

BACKGROUND - The use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL trial. It is not known, however, whether this effect is sustained for long-term follow-up.

 

METHODS - The IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28mm) to receive IVUS- (n=700) or angiography-guided (n=700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. Primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.

 

RESULTS - Five-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS-guidance and in 70 patients (10.7%) receiving angiography-guidance (hazard ratio [HR]=0.50, 95% confidence interval [CI]=0.34−0.75, P=0.001). The difference was mainly driven by a lower risk of target lesion revascularization (31 [4.8%] vs. 55 [8.4%], HR=0.54; 95% CI=0.33−0.89, P=0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS-guidance and in 31 patients (5.2%) receiving angiography-guidance (HR=0.53, 95% CI=0.29-0.95, P=0.031).

 

CONCLUSIONS - Compared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years’ post-implantation.