CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Active SB-P Versus Conventional Approach to the Protection of High-Risk Side Branches: The CIT-RESOLVE Trial Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS Associations between Blood Lead Levels and Coronary Artery Stenosis Measured Using Coronary Computed Tomography Angiography Long-term dual antiplatelet-induced intestinal injury resulting in translocation of intestinal bacteria into blood circulation increased the incidence of adverse events after PCI in patients with coronary artery disease Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study Adenosine and adenosine receptor-mediated action in coronary microcirculation Apolipoprotein A-V is a potential target for treating coronary artery disease: evidence from genetic and metabolomic analyses Global Approach to High Bleeding Risk Patients With Polymer-Free Drug-Coated Coronary Stents: The LF II Study 2019 Guidelines on Diabetes, Pre-Diabetes and Cardiovascular Diseases developed in collaboration with the EASD ESC Clinical Practice Guidelines Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial

Clinical TrialJanuary 9, 2020

JOURNAL:N Engl J Med. Article Link

Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement

OD Backer, GD Dangas, the GALILEO-4D Investigators et al. Keywords: leaflet thrombosis substudy; rivaroxaban vs clopidogrel; post TAVR

ABSTRACT


BACKGROUND - Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known.

 

METHODS - In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed.

 

RESULTS - A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, 8.8 percentage points; 95% confidence interval [CI], 16.5 to 1.9; P=0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, 20.0 percentage points; 95% CI, 30.9 to 8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively).

 

CONCLUSIONS - In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.)