CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Provisional versus elective two-stent strategy for unprotected true left main bifurcation lesions: Insights from a FAILS-2 sub-study Reduced Apolipoprotein M and Adverse Outcomes Across the Spectrum of Human Heart Failure Updated Expert Consensus Statement on Platelet Function and Genetic Testing for Guiding P2Y12 Receptor Inhibitor Treatment in Percutaneous Coronary Intervention rhACE2 Therapy Modifies Bleomycin-Induced Pulmonary Hypertension via Rescue of Vascular Remodeling Management of Antithrombotic Therapy in Atrial Fibrillation Patients Undergoing PCI: JACC State-of-the-Art Review Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation ACC/AHA Versus ESC Guidelines on Dual Antiplatelet Therapy JACC Guideline Comparison: JACC State-of-the-Art Review Three vs twelve months of dual antiplatelet therapy after zotarolimus-eluting stents: the OPTIMIZE randomized trial

Original ResearchVolume 13, Issue 1, January 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction

JC Choe, KS Cha, Korea Acute Myocardial Infarction Registry-National Institutes of Health Investigators et al. Keywords: acute myocardial infarction; biodegradable polymer drug-eluting stent; clinical outcome; second-generation durable polymer drug-eluting stent

ABSTRACT

OBJECTIVES - This study sought to compare outcomes between biodegradable polymer drug-eluting stent (BP-DES) and second-generation durable polymer drug-eluting stent (DP-DES) implantations for acute myocardial infarction (MI) using a nationwide dataset.

 

BACKGROUND - Data regarding outcomes of BP-DES versus second-generation DP-DES are inconclusive.

 

METHODS - Among 13,104 patients with acute MI in a nationwide registry who underwent percutaneous coronary intervention (November 2011 to December 2015), BP-DES and second-generation DP-DES were implanted in 2,261 (21.7%) and 8,182 patients (78.3%), respectively. Major adverse cardiac events (MACE) (all-cause death, recurrent MI, or any revascularization) were compared in multivariable Cox regression, propensity score (PS) matched, and underwent PS-adjusted analyses.

 

RESULTS - MACE occurred in 1,492 (14.3%) patients during a median 723-day follow-up. MACE were less frequent with BP-DES implantation than with second-generation DP-DES implantation (entire cohort hazard ratio [HR]: 0.845; 95% confidence interval [CI]: 0.740 to 0.965; PS-matched HR: 0.669; 95% CI: 0.550 to 0.814). Risk of all-cause death (entire cohort HR: 0.831; 95% CI: 0.692 to 0.997; PS-matched HR: 0.752; 95% CI: 0.495 to 0.931), cardiac death (entire cohort HR: 0.685; 95% CI: 0.542 to 0.865; PS-matched HR: 0.613; 95% CI: 0.463 to 0.872), recurrent MI (entire cohort HR: 0.662; 95% CI: 0.466 to 0.941; PS-matched HR: 0.611; 95% CI: 0.427 to 0.898), and heart failure readmission (entire cohort HR: 0.625; 95% CI: 0.447 to 0.875; PS-matched HR: 0.584; 95% CI: 0.385 to 0.887) was less with BP-DES implantation. There were no significant group differences in the incidences of any revascularization, stroke, and definite or probable stent thrombosis.

 

CONCLUSIONS -  In patients with acute MI who underwent percutaneous coronary intervention, BP-DES implantation is associated with improved outcomes compared with second-generation DP-DES implantation.