CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Venous and Arterial Thromboembolism in Patients With Cancer: JACC: CardioOncology State-of-the-Art Review Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial The Art of SAPIEN 3 Transcatheter Mitral Valve Replacement in Valve-in-Ring and Valve-in-Mitral-Annular-Calcification Procedures Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization Long-Term Outcomes of Patients With Mediastinal Radiation–Associated Coronary Artery Disease Undergoing Coronary Revascularization With Percutaneous Coronary Intervention and Coronary Artery Bypass Grafting 2020 ACC Expert Consensus Decision Pathway on Management of Bleeding in Patients on Oral Anticoagulants: A Report of the American College of Cardiology Solution Set Oversight Committee Thirty-Day Outcomes Following Transfemoral Transseptal Transcatheter Mitral Valve Replacement: Intrepid TMVR Early Feasibility Study Results Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation

Original ResearchVolume 13, Issue 1, January 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction

JC Choe, KS Cha, Korea Acute Myocardial Infarction Registry-National Institutes of Health Investigators et al. Keywords: acute myocardial infarction; biodegradable polymer drug-eluting stent; clinical outcome; second-generation durable polymer drug-eluting stent

ABSTRACT

OBJECTIVES - This study sought to compare outcomes between biodegradable polymer drug-eluting stent (BP-DES) and second-generation durable polymer drug-eluting stent (DP-DES) implantations for acute myocardial infarction (MI) using a nationwide dataset.

 

BACKGROUND - Data regarding outcomes of BP-DES versus second-generation DP-DES are inconclusive.

 

METHODS - Among 13,104 patients with acute MI in a nationwide registry who underwent percutaneous coronary intervention (November 2011 to December 2015), BP-DES and second-generation DP-DES were implanted in 2,261 (21.7%) and 8,182 patients (78.3%), respectively. Major adverse cardiac events (MACE) (all-cause death, recurrent MI, or any revascularization) were compared in multivariable Cox regression, propensity score (PS) matched, and underwent PS-adjusted analyses.

 

RESULTS - MACE occurred in 1,492 (14.3%) patients during a median 723-day follow-up. MACE were less frequent with BP-DES implantation than with second-generation DP-DES implantation (entire cohort hazard ratio [HR]: 0.845; 95% confidence interval [CI]: 0.740 to 0.965; PS-matched HR: 0.669; 95% CI: 0.550 to 0.814). Risk of all-cause death (entire cohort HR: 0.831; 95% CI: 0.692 to 0.997; PS-matched HR: 0.752; 95% CI: 0.495 to 0.931), cardiac death (entire cohort HR: 0.685; 95% CI: 0.542 to 0.865; PS-matched HR: 0.613; 95% CI: 0.463 to 0.872), recurrent MI (entire cohort HR: 0.662; 95% CI: 0.466 to 0.941; PS-matched HR: 0.611; 95% CI: 0.427 to 0.898), and heart failure readmission (entire cohort HR: 0.625; 95% CI: 0.447 to 0.875; PS-matched HR: 0.584; 95% CI: 0.385 to 0.887) was less with BP-DES implantation. There were no significant group differences in the incidences of any revascularization, stroke, and definite or probable stent thrombosis.

 

CONCLUSIONS -  In patients with acute MI who underwent percutaneous coronary intervention, BP-DES implantation is associated with improved outcomes compared with second-generation DP-DES implantation.