CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association Cardiac Shock Care Centers: JACC Review Topic of the Week Systems of Care for ST-Segment–Elevation Myocardial Infarction: A Policy Statement From the American Heart Association Association between urinary dickkopf-3, acute kidney injury, and subsequent loss of kidney function in patients undergoing cardiac surgery: an observational cohort study ACCF/SCAI/STS/AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization: A Report by the American College of Cardiology Foundation Appropriateness Criteria Task Force, Society for Cardiovascular Angiography and Interventions, Society of Thoracic Surgeons, American Association for Thoracic Surgery, American Heart Association, and the American Society of Nuclear Cardiology Endorsed by the American Society of Echocardiography, the Heart Failure Society of America, and the Society of Cardiovascular Computed Tomography Drug-Coated Balloon Versus Drug-Eluting Stent in Primary Percutaneous Coronary Intervention: A Feasibility Study Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT Development and validation of a simple risk score to predict 30-day readmission after percutaneous coronary intervention in a cohort of medicare patients A randomized multicentre trial to compare revascularization with optimal medical therapy for the treatment of chronic total coronary occlusions Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction

Original ResearchVolume 13, Issue 1, January 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Long-Term Outcomes of Biodegradable Versus Second-Generation Durable Polymer Drug-Eluting Stent Implantations for Myocardial Infarction

JC Choe, KS Cha, Korea Acute Myocardial Infarction Registry-National Institutes of Health Investigators et al. Keywords: acute myocardial infarction; biodegradable polymer drug-eluting stent; clinical outcome; second-generation durable polymer drug-eluting stent

ABSTRACT

OBJECTIVES - This study sought to compare outcomes between biodegradable polymer drug-eluting stent (BP-DES) and second-generation durable polymer drug-eluting stent (DP-DES) implantations for acute myocardial infarction (MI) using a nationwide dataset.

 

BACKGROUND - Data regarding outcomes of BP-DES versus second-generation DP-DES are inconclusive.

 

METHODS - Among 13,104 patients with acute MI in a nationwide registry who underwent percutaneous coronary intervention (November 2011 to December 2015), BP-DES and second-generation DP-DES were implanted in 2,261 (21.7%) and 8,182 patients (78.3%), respectively. Major adverse cardiac events (MACE) (all-cause death, recurrent MI, or any revascularization) were compared in multivariable Cox regression, propensity score (PS) matched, and underwent PS-adjusted analyses.

 

RESULTS - MACE occurred in 1,492 (14.3%) patients during a median 723-day follow-up. MACE were less frequent with BP-DES implantation than with second-generation DP-DES implantation (entire cohort hazard ratio [HR]: 0.845; 95% confidence interval [CI]: 0.740 to 0.965; PS-matched HR: 0.669; 95% CI: 0.550 to 0.814). Risk of all-cause death (entire cohort HR: 0.831; 95% CI: 0.692 to 0.997; PS-matched HR: 0.752; 95% CI: 0.495 to 0.931), cardiac death (entire cohort HR: 0.685; 95% CI: 0.542 to 0.865; PS-matched HR: 0.613; 95% CI: 0.463 to 0.872), recurrent MI (entire cohort HR: 0.662; 95% CI: 0.466 to 0.941; PS-matched HR: 0.611; 95% CI: 0.427 to 0.898), and heart failure readmission (entire cohort HR: 0.625; 95% CI: 0.447 to 0.875; PS-matched HR: 0.584; 95% CI: 0.385 to 0.887) was less with BP-DES implantation. There were no significant group differences in the incidences of any revascularization, stroke, and definite or probable stent thrombosis.

 

CONCLUSIONS -  In patients with acute MI who underwent percutaneous coronary intervention, BP-DES implantation is associated with improved outcomes compared with second-generation DP-DES implantation.