CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY Infective Endocarditis After Transcatheter Aortic Valve Replacement Ascending Aortic Length and Risk of Aortic Adverse Events: The Neglected Dimension New-onset atrial fibrillation after PCI and CABG for left main disease: insights from the EXCEL trial and additional studies Evolving concepts in the management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes 2019 AHA/ACC Clinical Performance and Quality Measures for Adults With High Blood Pressure: A Report of the American College of Cardiology/American Heart Association Task Force on Performance Measures Treatment and prevention of lipoprotein(a)-mediated cardiovascular disease: the emerging potential of RNA interference therapeutics Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Differences between the left main and other bifurcations

Review Article2018 Feb 1;252:229-233.

JOURNAL:Int J Cardiol. Article Link

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis

Kiaos A, Tziatzios I, Karamitsos TD et al. Keywords: Cardiovascular magnetic resonance; Coronary artery disease; Diagnostic accuracy meta-analysis; Stress perfusion

ABSTRACT


INTRODUCTION - The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.


METHODS - We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractionalflow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.


RESULTS - Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).


CONCLUSION - Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.


Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.