CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Impact of stent deformity induced by the kissing balloon technique for bifurcating lesions on in-stent restenosis after coronary intervention Multicenter Registry of Real-World Patients With Severely Calcified Coronary Lesions Undergoing Orbital Atherectomy: 1-Year Outcomes Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting Treating Bifurcation Lesions: The Result Overcomes the Technique The Hybrid Approach to Chronic Total Occlusion Percutaneous Coronary Intervention: Update From the PROGRESS CTO Registry Chronic Total Occlusion Interventions: Update on Current Tips and Tricks Bare metal or drug-eluting stent versus drug-coated balloon in non-ST-elevation myocardial infarction: the randomised PEPCAD NSTEMI trial Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study The European bifurcation club Left Main Coronary Stent study: a randomized comparison of stepwise provisional vs. systematic dual stenting strategies (EBC MAIN)

Review Article2018 Feb 1;252:229-233.

JOURNAL:Int J Cardiol. Article Link

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis

Kiaos A, Tziatzios I, Karamitsos TD et al. Keywords: Cardiovascular magnetic resonance; Coronary artery disease; Diagnostic accuracy meta-analysis; Stress perfusion

ABSTRACT


INTRODUCTION - The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.


METHODS - We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractionalflow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.


RESULTS - Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).


CONCLUSION - Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.


Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.