CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Outcomes of TTVI in Patients With Pacemaker or Defibrillator Leads: Data From the TriValve Registry Prevalence of potential drug-drug interactions in cancer patients treated with oral anticancer drugs Risk of Atrial Fibrillation According to Cancer Type: A Nationwide Population-Based Study Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation: A Randomised Non-Inferiority Trial Long-term Cardiopulmonary Consequences of Treatment-Induced Cardiotoxicity in Survivors of ERBB2-Positive Breast Cancer Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis Cardio-Oncology Services: rationale, organization, and implementation: A report from the ESC Cardio-Oncology council Rivaroxaban Is Associated With Higher Rates of Gastrointestinal Bleeding Than Other Direct Oral Anticoagulants: A Nationwide Propensity Score–Weighted Study Randomized study of doxorubicin-based chemotherapy regimens, with and without sildenafil, with analysis of intermediate cardiac markers Impact of Transcatheter Mitral Valve Repair on Preprocedural and Postprocedural Hospitalization Rates

Review Article2018 Feb 1;252:229-233.

JOURNAL:Int J Cardiol. Article Link

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis

Kiaos A, Tziatzios I, Karamitsos TD et al. Keywords: Cardiovascular magnetic resonance; Coronary artery disease; Diagnostic accuracy meta-analysis; Stress perfusion

ABSTRACT


INTRODUCTION - The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.


METHODS - We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractionalflow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.


RESULTS - Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).


CONCLUSION - Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.


Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.