CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Long-term outcomes following mini-crush versus culotte stenting for the treatment of unprotected left main disease: insights from the Milan and New-Tokyo (MITO) registry Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Cardiac Structural Changes After Transcatheter Aortic Valve Replacement: Systematic Review and Meta-Analysis of Cardiovascular Magnetic Resonance Studies ACC/AHA Versus ESC Guidelines on Dual Antiplatelet Therapy JACC Guideline Comparison: JACC State-of-the-Art Review Combined use of OCT and IVUS in spontaneous coronary artery dissection Subclinical and Device-Detected Atrial Fibrillation: Pondering the Knowledge Gap: A Scientific Statement From the American Heart Association Canagliflozin and Renal Outcomes in Type 2 Diabetes and Nephropathy Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement Primary Prevention Trial Designs Using Coronary Imaging: A National Heart, Lung, and Blood Institute Workshop Delirium After TAVR: Crosspassing the Limit of Resilience

Original Research2020 Jul 5;S0167-5273(20)33411-2.

JOURNAL:Int J Cardiol . Article Link

Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement

M Compagnone, G Marchetti, F Saia et al. Keywords: aortic valve stenosis; degenerated aortic valve bioprosthesis; prosthesis-patient mismatch; TAVR

ABSTRACT


BACKGROUND - Incidence and long-term clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) are still unclear.


METHODS - We enrolled 710 consecutive patients who underwent TAVR. PPM was defined as absent if the index orifice area (iEOA) was >0.85 cm2/m2, moderate if the iEOA was between 0.65 and 0.85 cm2/m2 or severe if the iEOA was <0.65 cm2/m2.

RESULTS - Among the 566 patients fulfilling the study criteria, the distribution of PPM was as follows: 50.5% none ( n = 286), 43% moderate PPM ( n = 243) and 6.5% severe PPM ( n = 37). At 5-year follow-up, patients with severe PPM had a significantly higher incidence of the combined endpoint of cardiovascular death, acute myocardial infarction and stroke ( p = .025) compared with the other patients. After adjusting the results for possible confounders, severe PPM remained an independent predictor of long-term adverse outcome (HR: 2.46; 95% Confidence Interval: 1.10–5.53). The independent predictors of severe PPM were valve-in-valve procedure and body mass index. Balloon-expandable valves were not associated with higher rates of severe PPM in comparison with self-expandable valves (5% vs. 8%, respectively, p = .245).


CONCLUSIONS -In our study severe PPM emerged as a risk factor for long-term major adverse cardiac and cerebrovascular events.