CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Minimum Core Data Elements for Evaluation of TAVR: A Scientific Statement by PASSION CV, HVC, and TVT Registry Evolving understanding of the heterogeneous natural history of individual coronary artery plaques and the role of local endothelial shear stress Percutaneous coronary intervention with drug-eluting stents versus coronary artery bypass grafting in left main coronary artery disease: an individual patient data meta-analysis Real-world clinical utility and impact on clinical decision-making of coronary computed tomography angiography-derived fractional flow reserve: lessons from the ADVANCE Registry Pulmonary hypertension related to congenital heart disease: a call for action Pulmonary Hypertension Caused by a Coconut Left Atrium C-reactive protein and prognosis after percutaneous coronary intervention and bypass graft surgery for left main coronary artery disease: Analysis from the EXCEL trial Rotational Atherectomy in acute STEMI with heavily calcified culprit lesion is a rule breaking solution ACCF/AHA 2009 expert consensus document on pulmonary hypertension a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents and the American Heart Association developed in collaboration with the American College of Chest Physicians; American Thoracic Society, Inc.; and the Pulmonary Hypertension Association Edoxaban versus Dual Antiplatelet Therapy for Leaflet Thrombosis and Cerebral Thromboembolism after TAVR: The ADAPT-TAVR Randomized Clinical Trial

Original Research2020 Jul 5;S0167-5273(20)33411-2.

JOURNAL:Int J Cardiol . Article Link

Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement

M Compagnone, G Marchetti, F Saia et al. Keywords: aortic valve stenosis; degenerated aortic valve bioprosthesis; prosthesis-patient mismatch; TAVR

ABSTRACT


BACKGROUND - Incidence and long-term clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) are still unclear.


METHODS - We enrolled 710 consecutive patients who underwent TAVR. PPM was defined as absent if the index orifice area (iEOA) was >0.85 cm2/m2, moderate if the iEOA was between 0.65 and 0.85 cm2/m2 or severe if the iEOA was <0.65 cm2/m2.

RESULTS - Among the 566 patients fulfilling the study criteria, the distribution of PPM was as follows: 50.5% none ( n = 286), 43% moderate PPM ( n = 243) and 6.5% severe PPM ( n = 37). At 5-year follow-up, patients with severe PPM had a significantly higher incidence of the combined endpoint of cardiovascular death, acute myocardial infarction and stroke ( p = .025) compared with the other patients. After adjusting the results for possible confounders, severe PPM remained an independent predictor of long-term adverse outcome (HR: 2.46; 95% Confidence Interval: 1.10–5.53). The independent predictors of severe PPM were valve-in-valve procedure and body mass index. Balloon-expandable valves were not associated with higher rates of severe PPM in comparison with self-expandable valves (5% vs. 8%, respectively, p = .245).


CONCLUSIONS -In our study severe PPM emerged as a risk factor for long-term major adverse cardiac and cerebrovascular events.