Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Physiology-Based Revascularization: A New Approach to Plan and Optimize Percutaneous Coronary Intervention: State-of-the-Art Review Prognostic Implication of Functional Incomplete Revascularization and Residual Functional SYNTAX Score in Patients With Coronary Artery Disease Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation: Outcomes at 2 years Management of pulmonary hypertension from left heart disease in candidates for orthotopic heart transplantation Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study Left ventricular remodelling and changes in functional measurements in patients undergoing transcatheter vs surgical aortic valve replacement: a head-to-head comparison Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Sex Differences in Instantaneous Wave-Free Ratio or Fractional Flow Reserve–Guided Revascularization Strategy

Original Research2020 Jul 5;S0167-5273(20)33411-2.

JOURNAL:Int J Cardiol . Article Link

Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement

M Compagnone, G Marchetti, F Saia et al. Keywords: aortic valve stenosis; degenerated aortic valve bioprosthesis; prosthesis-patient mismatch; TAVR

ABSTRACT


BACKGROUND - Incidence and long-term clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) are still unclear.


METHODS - We enrolled 710 consecutive patients who underwent TAVR. PPM was defined as absent if the index orifice area (iEOA) was >0.85 cm2/m2, moderate if the iEOA was between 0.65 and 0.85 cm2/m2 or severe if the iEOA was <0.65 cm2/m2.

RESULTS - Among the 566 patients fulfilling the study criteria, the distribution of PPM was as follows: 50.5% none ( n = 286), 43% moderate PPM ( n = 243) and 6.5% severe PPM ( n = 37). At 5-year follow-up, patients with severe PPM had a significantly higher incidence of the combined endpoint of cardiovascular death, acute myocardial infarction and stroke ( p = .025) compared with the other patients. After adjusting the results for possible confounders, severe PPM remained an independent predictor of long-term adverse outcome (HR: 2.46; 95% Confidence Interval: 1.10–5.53). The independent predictors of severe PPM were valve-in-valve procedure and body mass index. Balloon-expandable valves were not associated with higher rates of severe PPM in comparison with self-expandable valves (5% vs. 8%, respectively, p = .245).


CONCLUSIONS -In our study severe PPM emerged as a risk factor for long-term major adverse cardiac and cerebrovascular events.