CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Outcomes of procedural complications in transfemoral transcatheter aortic valve replacement Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Access Site and Outcomes for Unprotected Left Main Stem Percutaneous Coronary Intervention: An Analysis of the British Cardiovascular Intervention Society Database Pulmonary hypertension related to congenital heart disease: a call for action A randomized comparison of Coronary Stents according to Short or Prolonged durations of Dual Antiplatelet Therapy in patients with Acute Coronary Syndromes: a pre-specified analysis of the SMART-DATE trial Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation Streamlined reverse wire technique for the treatment of complex bifurcated lesions Impact of chronic obstructive pulmonary disease on prognosis after percutaneous coronary intervention and bypass surgery for left main coronary artery disease: an analysis from the EXCEL trial Superficial Calcium Fracture After PCI as Assessed by OCT ACCF/AHA 2009 expert consensus document on pulmonary hypertension a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents and the American Heart Association developed in collaboration with the American College of Chest Physicians; American Thoracic Society, Inc.; and the Pulmonary Hypertension Association

Clinical Trial2020 Nov 3;EIJ-D-20-00556.

JOURNAL:Eurointervention. Article Link

A randomized comparison of Coronary Stents according to Short or Prolonged durations of Dual Antiplatelet Therapy in patients with Acute Coronary Syndromes: a pre-specified analysis of the SMART-DATE trial

WJ Jang, JB Lee, YB Song et al. Keywords: 6-month vs. 12-month DAPT; ACS; DES

ABSTRACT

AIMS - We sought to compare biodegradable-polymer biolimus-eluting stents(BP-BES) with durable-polymer everolimus-eluting(DP-EES) and zotarolimus-eluting stents(DP-ZES) in patients with acute coronary syndrome(ACS) according to different duration of dual antiplatelet therapy(DAPT).


METHODS AND RESULTS - In the SMART-DATE trial, 2712 patients with ACS underwent randomization for allocation of DAPT (6-month [n=1357] or 12-month or longer [n=1355]) and type of stents (BP-BES [n=901]), DP-EES [n=904], or DP-ZES [n=907]). At 18 months, primary endpoint (a composite of cardiac death, myocardial infarction, or stent thrombosis) was 2.6% with BP-BES, 2.0% with DP-EES, and 2.1% with DP-ZES (HR 1.29, 95% CI 0.70-2.39, p=0.42 for BP-BES vs. DP-EES and HR 1.23, 95% CI 0.67-2.26, p=0.50 for BP-BES vs. DP-ZES). The treatment effect of BP-BES for the primary endpoint was consistent among patients receiving 6-month DAPT as well as those receiving 12-month or longer DAPT (BP-BES vs. DP-EES, pinteraction=0.48 and BP-BES vs. DP-ZES, pinteraction=0.87). After excluding 179 patients (101 in the BP-BES group) who did not receive allocated DES, per-protocol analysis showed similar results.


CONCLUSIONS - The risk of a composite of cardiac death, myocardial infarction, or stent thrombosis was not significantly different between patients receiving BP-BES vs. DP-EES or DP-ZES across short or prolonged duration of DAPT after ACS.