CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Hemodynamic, Functional, and Clinical Responses to Pulmonary Artery Denervation in Patients With Pulmonary Arterial Hypertension of Different Causes Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure Rivaroxaban for Thromboprophylaxis in High-Risk Ambulatory Patients With Cancer Long-Term Outcomes of Patients With Mediastinal Radiation–Associated Coronary Artery Disease Undergoing Coronary Revascularization With Percutaneous Coronary Intervention and Coronary Artery Bypass Grafting Systematic Review and Network Meta‐Analysis Comparing Bifurcation Techniques for Percutaneous Coronary Intervention 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview Implications of the local hemodynamic forces on the formation and destabilization of neoatherosclerotic lesions Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure Alcohol consumption, cardiac biomarkers, and risk of atrial fibrillation and adverse outcomes

Clinical Trial2020 Nov 3;EIJ-D-20-00556.

JOURNAL:Eurointervention. Article Link

A randomized comparison of Coronary Stents according to Short or Prolonged durations of Dual Antiplatelet Therapy in patients with Acute Coronary Syndromes: a pre-specified analysis of the SMART-DATE trial

WJ Jang, JB Lee, YB Song et al. Keywords: 6-month vs. 12-month DAPT; ACS; DES

ABSTRACT

AIMS - We sought to compare biodegradable-polymer biolimus-eluting stents(BP-BES) with durable-polymer everolimus-eluting(DP-EES) and zotarolimus-eluting stents(DP-ZES) in patients with acute coronary syndrome(ACS) according to different duration of dual antiplatelet therapy(DAPT).


METHODS AND RESULTS - In the SMART-DATE trial, 2712 patients with ACS underwent randomization for allocation of DAPT (6-month [n=1357] or 12-month or longer [n=1355]) and type of stents (BP-BES [n=901]), DP-EES [n=904], or DP-ZES [n=907]). At 18 months, primary endpoint (a composite of cardiac death, myocardial infarction, or stent thrombosis) was 2.6% with BP-BES, 2.0% with DP-EES, and 2.1% with DP-ZES (HR 1.29, 95% CI 0.70-2.39, p=0.42 for BP-BES vs. DP-EES and HR 1.23, 95% CI 0.67-2.26, p=0.50 for BP-BES vs. DP-ZES). The treatment effect of BP-BES for the primary endpoint was consistent among patients receiving 6-month DAPT as well as those receiving 12-month or longer DAPT (BP-BES vs. DP-EES, pinteraction=0.48 and BP-BES vs. DP-ZES, pinteraction=0.87). After excluding 179 patients (101 in the BP-BES group) who did not receive allocated DES, per-protocol analysis showed similar results.


CONCLUSIONS - The risk of a composite of cardiac death, myocardial infarction, or stent thrombosis was not significantly different between patients receiving BP-BES vs. DP-EES or DP-ZES across short or prolonged duration of DAPT after ACS.