The Burden of Cardiovascular Diseases Among US States, 1990-2016 Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement Mediterranean Diet and the Association Between Air Pollution and Cardiovascular Disease Mortality Risk Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Percutaneous Atriotomy for Levoatrial–to–Coronary Sinus Shunting in Symptomatic Heart Failure: First-in-Human Experience Bridging the Gap Between Epigenetic and Genetic in PAH Sequence variations in PCSK9, low LDL, and protection against coronary heart disease Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis The Role of the Pericardium in Heart Failure: Implications for Pathophysiology and Treatment Association of Statin Use With All-Cause and Cardiovascular Mortality in US Veterans 75 Years and Older

Original Research2018 Feb 15;253:45-49.

JOURNAL:Int J Cardiol. Article Link

Vascular response and healing profile of everolimus-eluting bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: A one-year optical coherence tomography analysis from the GHOST-CTO registry

La Manna A, Miccichè E, Capodanno D et al. Keywords: Bioresorbable vascular scaffold; Chronic total occlusion; Optical coherence tomography; Qualitative coronary analysis

ABSTRACT


BACKGROUND - Bioresorbable vascular scaffolds (BVS) have been heralded with potential benefits that are especially desired in long lesions, including chronic total occlusions (CTOs). Procedural feasibility and mid-term outcomes of BVS in CTOs have been reported. However, there is still a paucity of data regarding the vascular and healing response to BVS in CTOs evaluated by optical coherence tomography (OCT).


METHODS - This study included prospectively 21 patients who had a CTO lesion treated with a BVS. Angiography and OCT scan were recorded at either post-implantation and 1-year follow-up. Quantitative coronary angiography and OCT analyses were performed by an independent core laboratory.


RESULTS - The angiographic analysis showed a significant increase in the percentage of in-segment diameter stenosis at 1 year (11.89±9.5% vs. 21.84±11.7%; p=0.002). The OCT analysis showed a trend (p=0.07) towards increased mean scaffold area and significant reductions in mean lumen diameter (3.1±0.36mm vs. 2.85±0.47mm; p=0.0046), mean lumen area (7.8±1.73mm2 vs. 6.76±2mm2; p=0.0082) and minimal lumen area (5.26±1.86mm2 vs. 3.56±1.52mm2; p<0.0001). Malapposition area and volume decreased from 0.26±0.17mm2 to 0.08±0.1mm2 (p=0.0003) and from 14.17±12.92mm3 to 3.99±4.46mm3 (p=0.0014), respectively. The rate of uncovered or malapposed struts, measured at the frame level, was 5.29±6.48% at 1 year.


CONCLUSIONS - In a small series of CTO patients treated with BVS implantation, OCT outcomes at 1year displayed an overall favorable vascular response and healing profile.