CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Impact of Coronary Physiology on Contemporary Clinical Decision Making Noninvasive Screening for Pulmonary Hypertension by Exercise Testing in Congenital Heart Disease Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome Three-Year Outcomes of the DKCRUSH-V Trial Comparing DK Crush With Provisional Stenting for Left Main Bifurcation Lesions Echocardiographic Screening for Pulmonary Hypertension in Congenital Heart Disease Spontaneous Coronary Artery Dissection: Pathophysiological Insights From Optical Coherence Tomography Double-Kissing Culotte Technique for Coronary Bifurcation Stenting - Technical evaluation and comparison with conventional double stenting techniques Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology Prognostic Implications of Plaque Characteristics and Stenosis Severity in Patients With Coronary Artery Disease Physiological Stratification of Patients With Angina Due to Coronary Microvascular Dysfunction

Original Research2020 Jun 2;172(11):717-725.

JOURNAL:Ann Intern Med. Article Link

Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study

WJ Deng, SY Yin, D McMullin et al. Keywords: aneurysms; echocardiography; factor analysis; hyperlipidemia; hypertension; ischemic stroke; longitudinal studies; medical risk factors; stroke; transient ischemic attacks

ABSTRACT

BACKGROUND - Residual shunt is observed in up to 25% of patients after patent foramen ovale (PFO) closure, but its long-term influence on stroke recurrence currently is unknown.


OBJECTIVE - To investigate the association of residual shunt after PFO closure with the incidence of recurrent stroke and transient ischemic attack (TIA).

 

DESIGN - Prospective cohort study comparing stroke or TIA recurrence in patients with and without residual shunt after PFO closure.

 

SETTING - Single hospital center.

 

PARTICIPANTS - 1078 consecutive patients (mean age, 49.3 years) with PFO-attributable cryptogenic stroke who were undergoing percutaneous PFO closure were followed for up to 11 years.

 

MEASUREMENTS - Residual shunt was evaluated by transthoracic echocardiography with saline contrast. Primary outcome was a composite of the first recurrent ischemic stroke or TIA after PFO closure.

 

RESULTS - Compared with complete closure, the presence of residual shunt after PFO closure was associated with an increased incidence of recurrent stroke or TIA: 2.32 versus 0.75 events per 100 patient-years (hazard ratio [HR], 3.05 [95% CI, 1.65 to 5.62]; P < 0.001). This result remained robust after adjustment for important covariates, namely age; study period; device; presence of atrial septal aneurysm, hypertension, hyperlipidemia, diabetes, hypercoagulability, or hypermobile septum; and medication use (HR, 3.01 [CI, 1.59 to 5.69]; P < 0.001). Further stratification based on shunt size revealed that moderate or large residual shunts were associated with a higher risk for stroke or TIA recurrence (HR, 4.50 [CI, 2.20 to 9.20]; P < 0.001); the result for small residual shunts was indeterminate (HR, 2.02 [CI, 0.87 to 4.69]; P = 0.102).

 

LIMITATION - Nonrandomized study with potential unmeasured confounding.

 

CONCLUSION -  Among patients undergoing PFO closure to prevent future stroke, the presence of residual shunt, particularly a moderate or large residual shunt, was associated with an increased risk for stroke or TIA recurrence.

 