CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Fractional Flow Reserve–Guided PCI as Compared with Coronary Bypass Surgery Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation: Outcomes at 2 years Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease: PICCOLETO II Randomized Clinical Trial Percutaneous Pulmonary Angioplasty for Patients With Takayasu Arteritis and Pulmonary Hypertension Bare metal or drug-eluting stent versus drug-coated balloon in non-ST-elevation myocardial infarction: the randomised PEPCAD NSTEMI trial

Original Research2020 Jun 2;172(11):717-725.

JOURNAL:Ann Intern Med. Article Link

Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study

WJ Deng, SY Yin, D McMullin et al. Keywords: aneurysms; echocardiography; factor analysis; hyperlipidemia; hypertension; ischemic stroke; longitudinal studies; medical risk factors; stroke; transient ischemic attacks

ABSTRACT

BACKGROUND - Residual shunt is observed in up to 25% of patients after patent foramen ovale (PFO) closure, but its long-term influence on stroke recurrence currently is unknown.


OBJECTIVE - To investigate the association of residual shunt after PFO closure with the incidence of recurrent stroke and transient ischemic attack (TIA).

 

DESIGN - Prospective cohort study comparing stroke or TIA recurrence in patients with and without residual shunt after PFO closure.

 

SETTING - Single hospital center.

 

PARTICIPANTS - 1078 consecutive patients (mean age, 49.3 years) with PFO-attributable cryptogenic stroke who were undergoing percutaneous PFO closure were followed for up to 11 years.

 

MEASUREMENTS - Residual shunt was evaluated by transthoracic echocardiography with saline contrast. Primary outcome was a composite of the first recurrent ischemic stroke or TIA after PFO closure.

 

RESULTS - Compared with complete closure, the presence of residual shunt after PFO closure was associated with an increased incidence of recurrent stroke or TIA: 2.32 versus 0.75 events per 100 patient-years (hazard ratio [HR], 3.05 [95% CI, 1.65 to 5.62]; P < 0.001). This result remained robust after adjustment for important covariates, namely age; study period; device; presence of atrial septal aneurysm, hypertension, hyperlipidemia, diabetes, hypercoagulability, or hypermobile septum; and medication use (HR, 3.01 [CI, 1.59 to 5.69]; P < 0.001). Further stratification based on shunt size revealed that moderate or large residual shunts were associated with a higher risk for stroke or TIA recurrence (HR, 4.50 [CI, 2.20 to 9.20]; P < 0.001); the result for small residual shunts was indeterminate (HR, 2.02 [CI, 0.87 to 4.69]; P = 0.102).

 

LIMITATION - Nonrandomized study with potential unmeasured confounding.

 

CONCLUSION -  Among patients undergoing PFO closure to prevent future stroke, the presence of residual shunt, particularly a moderate or large residual shunt, was associated with an increased risk for stroke or TIA recurrence.

 

PRIMARY FUNDING SOURCE -  National Institutes of Health.