CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens Right ventricular expression of NT-proBNP adds predictive value to REVEAL score in patients with pulmonary arterial hypertension One-Year Outcomes of Orbital Atherectomy of Long, Diffusely Calcified Coronary Artery Lesions Clinical Characteristics and Long-Term Outcomes of Rotational Atherectomy-J2T Multicenter Registry North American Expert Review of Rotational Atherectomy Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation Procedural Success and Outcomes With Increasing Use of Enabling Strategies for Chronic Total Occlusion Intervention Incidence and Standardized Definitions of Mitral Valve Leaflet Adverse Events After Transcatheter Mitral Valve Repair: the EXPAND Study Trends in Usage and Clinical Outcomes of Coronary Atherectomy: A Report From the National Cardiovascular Data Registry CathPCI Registry

Original Research2020 Jun 2;172(11):717-725.

JOURNAL:Ann Intern Med. Article Link

Residual Shunt After Patent Foramen Ovale Closure and Long-Term Stroke Recurrence: A Prospective Cohort Study

WJ Deng, SY Yin, D McMullin et al. Keywords: aneurysms; echocardiography; factor analysis; hyperlipidemia; hypertension; ischemic stroke; longitudinal studies; medical risk factors; stroke; transient ischemic attacks

ABSTRACT

BACKGROUND - Residual shunt is observed in up to 25% of patients after patent foramen ovale (PFO) closure, but its long-term influence on stroke recurrence currently is unknown.


OBJECTIVE - To investigate the association of residual shunt after PFO closure with the incidence of recurrent stroke and transient ischemic attack (TIA).

 

DESIGN - Prospective cohort study comparing stroke or TIA recurrence in patients with and without residual shunt after PFO closure.

 

SETTING - Single hospital center.

 

PARTICIPANTS - 1078 consecutive patients (mean age, 49.3 years) with PFO-attributable cryptogenic stroke who were undergoing percutaneous PFO closure were followed for up to 11 years.

 

MEASUREMENTS - Residual shunt was evaluated by transthoracic echocardiography with saline contrast. Primary outcome was a composite of the first recurrent ischemic stroke or TIA after PFO closure.

 

RESULTS - Compared with complete closure, the presence of residual shunt after PFO closure was associated with an increased incidence of recurrent stroke or TIA: 2.32 versus 0.75 events per 100 patient-years (hazard ratio [HR], 3.05 [95% CI, 1.65 to 5.62]; P < 0.001). This result remained robust after adjustment for important covariates, namely age; study period; device; presence of atrial septal aneurysm, hypertension, hyperlipidemia, diabetes, hypercoagulability, or hypermobile septum; and medication use (HR, 3.01 [CI, 1.59 to 5.69]; P < 0.001). Further stratification based on shunt size revealed that moderate or large residual shunts were associated with a higher risk for stroke or TIA recurrence (HR, 4.50 [CI, 2.20 to 9.20]; P < 0.001); the result for small residual shunts was indeterminate (HR, 2.02 [CI, 0.87 to 4.69]; P = 0.102).

 

LIMITATION - Nonrandomized study with potential unmeasured confounding.

 

CONCLUSION -  Among patients undergoing PFO closure to prevent future stroke, the presence of residual shunt, particularly a moderate or large residual shunt, was associated with an increased risk for stroke or TIA recurrence.

 

PRIMARY FUNDING SOURCE -  National Institutes of Health.