CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Rationale and design of the comparison between a P2Y12 inhibitor monotherapy versus dual antiplatelet therapy in patients undergoing implantation of coronary drug-eluting stents (SMART-CHOICE): A prospective multicenter randomized trial Outcomes in patients treated with ticagrelor or clopidogrel after acute myocardial infarction: experiences from SWEDEHEART registry SR-B1 Drives Endothelial Cell LDL Transcytosis via DOCK4 to Promote Atherosclerosis Use of Risk Assessment Tools to Guide Decision-Making in the Primary Prevention of Atherosclerotic Cardiovascular Disease : A Special Report From the American Heart Association and American College of Cardiology A Platelet Function Modulator of Thrombin Activation Is Causally Linked to Cardiovascular Disease and Affects PAR4 Receptor Signaling Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study Intravascular Imaging and 12-Month Mortality After Unprotected Left Main Stem PCI: An Analysis From the British Cardiovascular Intervention Society Database Rationale and design of a prospective substudy of clinical endpoint adjudication processes within an investigator-reported randomised controlled trial in patients with coronary artery disease: the GLOBAL LEADERS Adjudication Sub-StudY (GLASSY) Statin Effects on Vascular Calcification: Microarchitectural Changes in Aortic Calcium Deposits in Aged Hyperlipidemic Mice Clinical Outcomes and Cost-Effectiveness of Fractional Flow Reserve-Guided Percutaneous Coronary Intervention in Patients With Stable Coronary Artery Disease: Three-Year Follow-Up of the FAME 2 Trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation)

Clinical TrialVolume 10, Issue 8, August 2017, Pages 869-879

JOURNAL:JACC Cardiovasc Imaging. Article Link

In Vivo Calcium Detection by Comparing Optical Coherence Tomography, Intravascular Ultrasound, and Angiography

Wang X, Matsumura M, Mintz GS et al. Keywords: angiography; calcification; intravascular ultrasound; optical coherence tomography

ABSTRACT

OBJECTIVES- The aim of this study was to evaluate optical coherence tomography (OCT) and intravascular ultrasound (IVUS) versus coronary angiography in the assessment of target lesion calcification and its effect on stent expansion.


BACKGROUD - IVUS is more sensitive than angiography in the detection of coronary artery calcium, but the relationship among IVUS, OCT, and angiography has not been studied.


METHODS - Overall, 440 lesions (440 patients with stable angina) underwent OCT- and IVUS-guided stent implantation. Coronary calcification was evaluated using: 1) angiography; 2) IVUS (maximum calcium angle and the surface pattern); and 3) OCT (mean and maximum calcium angle, calcium length, and maximum calciumthickness).


RESULTS - Median patient age was 66 years, and 82.5% were men. Among 440 lesions, calcium was detected by angiography in 40.2%, IVUS in 82.7%, and OCT in 76.8%. The maximum calcium angle, maximum calciumthickness, and calcium length by OCT or IVUS increased in relation to the increasing severity of angiographically visible calcium. In 13.2% of lesions with IVUS-detected calcium, calcium was either not visible or was underestimated (>90° smaller maximum arc) by OCT mostly due to superficial OCT plaque attenuation. In 21.6% of lesions with IVUS calcium angle >180°, angiography did not detect any calcium; these lesions had thinner and shorter calcium deposits as assessed using OCT, and final minimum stent area was larger compared to those with angiographically visible calcium. In lesions with thinner calcium deposits by OCT, IVUS detected a smooth surface with reverberations whereas thick calcium deposits were associated with an irregular surface without reverberations.


CONCLUSIONS - Angiographic detection of target lesion coronary calcium (compared to intravascular imaging) has not changed in the past 2 decades, and angiographically invisible calcium (only detectable by IVUS or OCT) did not appear to inhibit stent expansion.